General Maintenance Procedures
Page 15
Replace bearing.
Galling
Metal smears on roller ends because of overheating, lubricant
failure or overload.
Replace bearing - check seals and check for proper lubrication.
Abrasive Step Wear
Pattern on roller ends caused by fine abrasives.
Clean all parts and housings, check all parts and housings,
check seals and bearings and replace if leaking, rough or noisy.
Figure 4