OP000599
Inspection, Maintenance and Adjustment
4-52
2,000 HOUR / YEARLY SERVICE
Perform All Daily, 50, 250, 500 and 1,000
Hour Service Checks
Change Swing Reduction Device Oil
NOTE:
Change swing reduction device oil after first 250
hours of operation or rebuild and every 2,000 hours
thereafter.
1.
Set a container under excavator.
2.
Remove cap (3, Figure 87) and install hose (4) to drain the
swing reduction device oil.
NOTE:
Dispose of drained fluids according to local
regulations.
3.
After draining oil, remove hose and install cap.
4.
Remove breather/fill cap (2, Figure 86) and add oil to "H"
mark on dipstick (1).
2
1
FG009555
Figure 86
WARNING!
The gear oil is very hot after the machine has been
operating. Shut all systems down and allow them to cool.
3
FG009556
Figure 87
L
H
FG000419
Figure 88