OP000599
4-19
Inspection, Maintenance and Adjustment
Check Fuel Prefilter and Drain Water As
Required
1.
A fuel prefilter is inside the left rear side access door.
2.
Open the access door on left rear side of the machine.
3.
It is necessary to drain the collected water if the bowl is full
of water or sediment.
4.
Position a small container under fuel prefilter. Drain water
or sediment by opening drain valve (2, Figure 24) on
bottom of bowl (1).
NOTE:
Dispose of drained fluids according to local
regulations.
5.
Close drain valve.
Figure 23
PreLine
FG009554
FG000438
1
2
close
open
Figure 24