OP000509
4-45
Inspection, Maintenance and Adjustment
Clean Outer Filter of Air Cleaner
NOTE:
Clean outer filter every 250 hours / monthly service.
NOTE:
If air cleaner clogged warning light (Figure 65) on
instrument panel comes "ON" the air cleaner must be
serviced.
NOTE:
When working in severely dusty conditions, the
service interval should be shortened.
1.
Locate the air cleaner assembly.
NOTE:
When it reaches every 250 hours or If indicator
light (Figure 65) on instrument panel comes
"ON" the air cleaner must be serviced.
NOTE:
Replace outer filter after cleaning 4 times or
every 1,000 hours / 6 months service.
2.
Remove and clean rubber evacuator valve (1, Figure
67) from bottom of air cleaner housing cover (2, Figure
67). Inspect seal lips for wear or damage. Replace
valve if necessary.
NOTE:
Install evacuator valve with lips parallel to the
cover.
3.
Remove the access cover (2, Figure 67) by loosening
the latches (3).
4.
Remove the outer filter (4, Figure 67) from the housing.
Do not remove inner filter (5).
10
0
5
20
30
25
15
40
30
50
20
0
10
FG008103
F/R
Figure 65
WARNING!
Never clean or attempt to remove the air cleaner filter if
the engine is running.
This will allow dirt to be sucked into engine and cause
serious engine damage
Always turn engine "OFF" before servicing air cleaner.
Figure 66
1
4
5
2
3
FG000702
Figure 67
Содержание DL200
Страница 2: ......
Страница 6: ...K1024537E Table of Contents IV ...
Страница 7: ...K1024537E I I Presentation 1Presentation PRESENTATION FG008047 Figure 1 ...
Страница 17: ...OP000506 1 5 Safety 1 3 10 12 6 4 11 5 9 8 3 7 10 9 4 6 2 FG008049 Figure 1 ...
Страница 60: ...OP000506 Safety 1 48 ...
Страница 112: ...OP000507 Operating Controls 2 52 CD Player Optional AST DIR FG000109 Figure 101 ...
Страница 122: ...OP000507 Operating Controls 2 62 ...
Страница 232: ...OP000509 Inspection Maintenance and Adjustment 4 88 ...
Страница 242: ...OP000040 Troubleshooting 6 8 ...
Страница 252: ...OP000510 Specification 7 10 ...