1800-065 Issued 1-19
Version D

PH LINE

16VAC
16VAC
E GND

POWER

POWER

SOURCE

SYSTEM A

PROGRAM

MASTER

CODE

NORMAL

DATA

RESET

LINK

SYSTEM B

ON/OFF

Button

Ethernet

1800-010

PH LINE

DATA OUT

BUSY OUT
BUSY IN
GROUND

DATA IN

DATA OUT

RS 232

RS 232

BUSY OUT
BUSY IN
GROUND

DATA IN

PH LINE
PH LINE

Cycle Power to the Cellular Module:

 

 

This will cycle power to the cellular module if power is ON or it will turn ON the module if it is OFF. This allows the module to re-connect with the cellular network.
Slide Switch to Program:

   *

87 Master Code(Beep) 01

*

(Beep) 1

*

(Beep) to 

cycle power

  or  0

*

(Beep) to 

NOT cycle power

.

Hang up Phone   Slide switch back to Normal if done programming.

TCP/RS 232 Factory Defaults

This will RESET the TCP/RS 232 module back to factory defaults. 
Slide switch to Program:
   

*

87 Master Code(Beep) 02

*

(Beep) 1

*

(Beep) to 

reset defaults

 or 0

*

(Beep) to 

NOT reset defaults

Hang up phone. Slide switch back to Normal if done programming.

Cycle Power to Cellular Module Schedule:

This schedules the number of days between automatic power cycling of the cellular module. This allows the module to re-connect with the cellular network after 
periods of non-usage. The revision letter of YOUR specific circuit board will restrict programming to either “number of days-Rev A ONLY” OR “number of hours-Rev B 
or higher”.

 

“Rev A” Circuit Board ONLY, “0-9” number of days:

 

Note: 0= no cycle. 1= every day, 2= every two days, 3= every three days etc. Up to every 9 days.

 

Factory default setting: every 3 days.

 

Slide switch to Program

 

   

*

87 Master Code(Beep) 03

*

(Beep) 0-9

*

(Beep) 

number of days

 to cycle power.

 

Hang up phone. Slide switch back to Normal if done programming.

 

“Rev B or higher” Circuit Boards, “00-99” number of hours:

 

Note: 00= no cycle. 01= every hour, 02= every two hours, 03= every three hours etc. Up to every 99 hours.

 

Factory default setting: every 3 hours.

 

Slide switch to Program

 

   

*

87 Master Code(Beep) 03

*

(Beep) 00-99

*

(Beep) 

number of hours

 to cycle power.

 

Hang up phone. Slide switch back to Normal if done programming.

Number of Rings to Answer Call:

Sets the number of rings for an incoming call before the cellular system will answer. 2= two rings, 3= three rings, etc. Up to 9 rings. (2-9)
Normally the 1830 will answer on the second ring. In this case the cellular system will listen in for DTMF tones 

*

87 Master code. If received, the cellular system will 

stay on the line for programming while the 1830 will hang up. If any other DTMF tones are received, the cellular system will ignore them. If the 1830 does not answer 
on the second ring, the cellular system will answer on the programmed number of rings.

Factory default setting: 5 rings.

Slide switch to Program
   

*

87 Master Code(Beep) 04

*

(Beep) 2-9

*

(Beep) 

number of rings

 before answering call. 

Hang up Phone. Slide switch back to Normal if done programming.

TCP/RS 232 Power Cycle:

Sometimes it is necessary to cycle power to the TCP/RS 232 module to re-establish an Ethernet connection to the cellular module.
Slide switch to Program
   

*

87 Master Code(Beep) 05

*

(Beep) 1

*

(Beep) to 

cycle power

 to TCP/RS 232 module or 0

*

(Beep) to 

not cycle power

.

Hang up phone. Slide switch back to Normal if done programming.

Multiple Program Note: 

Once the 

*

87 Master Code(Beep) has been keyed in and programming mode is entered, It is possible to program 

multiple

 functions without 

leaving the programming mode. Just complete one program step and then go to the next.

 Programming 

Example:

 Master Code is 1234. Cycle power to the cellular module and then cycle power to the TCP/RS 232 module.

 

   *

871234(Beep) 01

*

(Beep) 1

*

(Beep) 05

*

(Beep) 1

*

(Beep)     Hangup

Programming

PH LINE

SYSTEM A

RJ11

PHONE

JACK

PH LINE

DATA OUT

RS 232

BUSY OUT
BUSY IN
GROUND

DATA IN

PROGRAM

NORMAL

enter

programming

mode

exit

programming

mode

cycle

module

power

cycle

TCP/RS 232

power

The cellular system will remember the commands 
received and execute them in order when program 
mode is exited.

Program Slide Switch - 

Slide this switch to program when programming the board LOCALLY

using a touch tone telephone. Be sure to switch back to Normal when finished programming.
Cellular voice will 

NOT

 work with program slide switch set to 

PROGRAM

.

Setting the Master Code for Voice/Data Cellular System:

Slide switch to Program
Connect a touch tone phone to 

System A

 phone terminals. Press and release the Master Code push button. Enter on the phone the new 4 digit Master 

Code and then press 

*

. A tone should be heard in the phone ear piece. The new master code is now programmed. Hang up the phone to end programming. 

Note: The cellular system’s master code 

MUST

 be the 

SAME

 as 

System A

 1830 master code. This is how the DKS cellular server identifies the cellular 

system to contact it if needed. Set the slide switch back to Normal if done, or leave in Program if more programming will be done.

MASTER

CODE

Rev A

POW

SOUR

SYSTEM A

Circuit

Board

Revision

Letter

OR

Set program slide 
switch to 

NORMAL

 

for dial tone.

Содержание 1800-080

Страница 1: ...location and the 1830 system s has already been setup and functioning including the master code and multiple system programming if 2 1830s are being used Prior to Installation An existing cellular phone will be needed to test the signal strength of DoorKing s cellular network in the desired installation location a smart phone is preferred Analog modems Dial Up DO NOT work on a cellular network BEF...

Страница 2: ...ed shall be in accordance with National Electrical Code ANSI NFPA 70 Permissible wire sizes for the terminals 12 26 AWG Type of wiring to be used on ALL external devices A Type CL2 CL2P CL2R or CL2X B Other cable with equivalent or better electrical mechanical and flammability ratings Watertight Conduit and Connectors Wire Runs Cellular System TELE PHO NE ENTR Y SYS TEM HOL D TO SCA N OPER ATING I...

Страница 3: ... telephone service and programming for TWO 1830s designated as System A and System B The telephone line is SHARED with both 1830s Each 1830 MUST be programmed for Multiple Systems see specific 1830 Installation Owner s instruction manual for more information RS 232 RS 232 RS 232 A RS 232 A LEDs External Antenna Connection RS 232 B LEDs Cellular Power Phone Jack Board Power LED RS 232 B The EARTH G...

Страница 4: ...re registering a cellular system on DoorKing s Cellular Server you will need SIM ID number located on the cellular module number is unique for each cellular module Master Code of System A Master Code of System B if connected MUST be a different master code than System A OPTION 1 Go to DKS cellular website https dksdb dksoftware com NewUserRegChoice aspx to register follow instructions on website O...

Страница 5: ...the line for programming while the 1830 will hang up If any other DTMF tones are received the cellular system will ignore them If the 1830 does not answer on the second ring the cellular system will answer on the programmed number of rings Factory default setting 5 rings Slide switch to Program 87 Master Code Beep 04 Beep 2 9 Beep number of rings before answering call Hang up Phone Slide switch ba...

Страница 6: ...LED lights on the Voice Data cellular circuit board During a data transfer the yellow Ethernet data LED should be flashing The data LED near the RJ45 cable should be flashing The RS 232 LEDs should be flashing for the proper system either A or B indicating attempted data transfer If the wrong RS 232 LEDs are flashing A and B systems are mixed up Check the 1830 baud rate setting It should be 19200b...

Страница 7: ...vice meets the government s requirements for exposure to radio waves This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency RF energy set by the Federal Communications Commission of the U S Government This device complies with FCC radiation exposure limits set forth for an uncontrolled environment Glossary for UL 294 Compliance ACCESS CONTROL SYS...

Отзывы: