background image

3

safety InstructIons

operator

swing-3000

swing-5000

Weight, kg

10

11 

Supply voltage, V/hz

220–240/50 

rated power, W

150

Intensity, %

50

protection rating

Ip54

Gear ratio

1/36

rod speed, mm/s

15

force, n

3 000

Working temperature range, °c

–40…+55

capacitor, mf

10

1.3. operator paCkaGe

upon receiving the operator, unpack it and inspect it carefully. If any signs of damage are observed, please contact your 

supplier.

The operator components included in the standard package are listed in the following table.

name

Quantity

1

Operator

2

2

rear fastening bracket

2

3

front fastening bracket

2

4

Set of fasteners

1

5

control unit with case

1

6

Keyswitch

1

7

Signal lamp

1

8

photo cells

1

9

user manual

1

1.2.   teChnICal speCIfICatIons

2.   safety InstruCtIons

WarnInG!

 

Important safety InstruCtIons! 

It is important for the safety of persons to follow safety instructions. 

Save these instructions.

 

 follow all instructions since incorrect installation can lead to severe injury.

 

 Swing-3000/5000 was designed for automation of a street double leaf swinging gate with a load bearing structure. do not 
use the operator for other than intended purposes.

 

 doorhan shall not be held responsible in case of injury caused by misuse of the product.

 

 prior to installation make sure that the gate moves smoothly.

 

 Installation must be performed in accordance with the standards en12453 and en 12445. for countries, which are not 
ec members, these requirements are to be met.

 

 check if the gate conforms to the standards en12604 and en 12605 (see documentation accompanying the gate). for 
countries, which are not ec members, the above mentioned requirements shall be met in order to obtain an appropriate 
safety level.

Содержание SWING-3000

Страница 1: ...Safety instructions Operator unit Operator Installation Electrical Connections Extreme Positions Adjustment operator Programming programming of remote controls Release Operation maintenance Troubleshooting 2 2 3 5 5 8 10 11 12 12 12 13 Installation and Operating Manual ...

Страница 2: ... remote control unit in a shockproof hermetic case 1 1 Range of use Leaf width m Leaf weight kg 2 00 1000 2 50 800 3 00 600 4 00 500 5 00 400 Leaf width m Leaf weight kg 2 00 800 2 50 600 3 00 400 Swing 3000 Swing 5000 CONTENTS 1 General Information 2 1 1 Range of use 2 1 2 Technical specifications 3 1 3 Operator package 3 2 Safety instructions 3 3 Operator unit 5 4 operator installation 5 4 1 Too...

Страница 3: ...tions WARNING Important safety instructions It is important for the safety of persons to follow safety instructions Save these instructions Follow all instructions since incorrect installation can lead to severe injury Swing 3000 5000 was designed for automation of a street double leaf swinging gate with a load bearing structure Do not use the operator for other than intended purposes DoorHan shal...

Страница 4: ...ystem DoorHan is not responsible for unstable work of the automatic system when using safety devices and accessories which are produced by other manufactures without agreement with DoorHan Never leave the electric motors in released condition This may cause uncontrolled movement of the gate leaves and consequently their breakdown Do not use the operator if it needs repair or adjustment as installa...

Страница 5: ... M8 50 M8 10 5 6 2 Гайка М8 Nut M8 Stroke Stroke 793 300 993 500 Swing 3000 Swing 5000 88 126 88 126 1 Set of spanners 2 Set of slotted and cross screwdrivers 3 Set of drills for metal 4 Set of drills for concrete 5 Pliers 6 Hacksaw for metal 7 Electric drill 8 Tape measure folding rule 4 1 Tools 4 operator installation ...

Страница 6: ...K OF INJURY Have a qualified technician lay the cables 220 240 V AC The cables must be laid in protective corrugated tubes Avoid contact of cables and moving parts of the door In case of supply cable damage use the suitable type of the cable Cables needed for installation of the Swing 3000 5000 operator and accessories if available cable 2 0 5 mm2 photocell transmitter stepped control button cable...

Страница 7: ...tral hole and of the gate hinge shank The rear bracket has several holes which make installation of the operator easier and allow changing of the gate opening angle Depending on the position of the gate hinges you can lengthen or shorten the rear bracket Warning Increase of dimension B results in decrease of the gate opening angle and leaf angle speed and in increase of the operator s linear force...

Страница 8: ...d fasten the front bracket to the gate leaf Наружняя сторона объекта Внутренняя сторона объекта Дополнительный кронштейн D B A External side of the object Internal side of the object Additional bracket 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 19 20 21 12 PE N L COM OP CL LAMP S B S PED OP CL COM STOP 24V S Lock COM OP CL FOTO 2 3 4 5 2 2 I COM F Tr COM NO NC 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17...

Страница 9: ...device responses when the operator is activated than the gate leaves reverse or stop immediately and continue to move afterwards Response of the device does not effect operation of the closing gate If the gate is closed and the device has responded the gate will remain stationary WARNING If these terminals are not used install a jumper between contacts 13 15 14 15 CL FOTO contacts for connection o...

Страница 10: ... Unscrew 2 tapping screws and remove the cover 2 Unscrew 2 tapping screws and remove the lead screw casing 6 3 Closed position 1 Put the gate leaf in fully closed position which can be determined by the mechanical stop 2 Unscrew fastening of the closing microswitch 3 Move the end microswitch along the guide until the microswitch contacts with the slide 4 Move the microswitch ahead until the micros...

Страница 11: ... and release The leaves will begin to open After they reach the limit switches the leaves will stop At this moment give a control command Programming is done Press F again to leave the basic programming mode When the next control command is given the leaves will start moving in accordance with the programmed operation mode Display Function On default A Programming of pause time before automatic cl...

Страница 12: ...be carried out only by a qualified technician trained and certified at an authorized DoorHan centre Be sure that after completion of installation the installer has shown the user how to release the door in case of emergency and has given instructions on proper operation and maintenance of the automated system When carrying out maintenance it is recommended to use DoorHan original spare parts Carry...

Страница 13: ...ent Remove the obstruction Bad wiring connection Check reliability of electric wiring connection Operator is released Engage the operator Operator stops suddenly Thermal protection is active Let the operator cool The gate does not open or close completely Wrong adjustment of limit switches Adjust the limit switches Wrong operator programming Reprogram the operator ...

Страница 14: ...14 Notes ...

Страница 15: ...15 Notes ...

Страница 16: ... our company and believe that you will be satisfied with its quality For information on purchasing distribution and servicing contact DoorHan central office at Kralovsky VRCH 2018 Kadan 43201 Czech Republic Telephone 420 474 319 111 E mail europe doorhan com www doorhan cz ...

Отзывы: