MENAPRO20032009
APRO 20
ENGLISH
The LED on the detector front panel (Fig. 2-B) will indicate the detection of a movement,
for all the time the relay is excited.
A
E
F B
B A
Fig.1
Fig.2
Wire colour
Description
Red
12-24 V
AC/DC
Black
12-24 V
AC/DC
Green
COM relay contact
Brown
NO contact (when device is not powered)
Blue
NC contact (when device is not powered)
Tab.1
RELAY CONTACT SETTING
APRO 20
has a relay with switching contact.
According to the setting of the dip-switch 3 (Fig. 1-B) in the lower section of the detector,
the combinations described in table 2 can be obtained.
These conditions are valid when the device is powered.
Via Cagliari, 19 - Tel. +390112482361