Door, Alarm, Acoustic Signal,
Door Bell Settings
Door Open Detection
Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic
contact of the lock, if the door is opened normally, but not closed after 1 minute, the internal buzzer will bleep
automatically to remind people to close the door and continue for 1 minute before switching off automatically
Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact of the
lock, if the door is forced open, the internal buzzer and alarm output will both operate
To disable door open detection
6 0 #
(Default)
To enable door open detection
6 1 #
It is optional to connect the D_IN line to LOCK1 or LOCK 2
Keypad Lockout & Alarm Output options
. If there are 10 invalid cards or 10 incorrect PIN numbers in a
10 minute period either the keypad will lockout for 10 minutes or the alarm will operate for 10 minutes,
depending on the option selected below
Normal status: No keypad lockout
or alarm
7 0 #
(Default)
Keypad Lockout
7 1 #
Alarm Output
7 2 #
Alarm output time
To set the alarm output time
8 1-3 #
(Default is 1 minute)
(1-3 minutes available)
Acoustic Signal
The acoustic signal can be set on or off. When on, the keypad will bleep when the key buttons are pressed,
when off, the keypad will be in silent
Normal status: On
8 6 #
(Default)
Acoustic signal Off
8 7 #
Change Relay 2 to Door Bell
(When there is no need to operate a second door, relay 2 can be set to operate as a door bell. The wiring is
connecting the door bell to COM2 and NO2. Press #, and the keypad will send the signal to the door bell
Relay 2
8 8 #
(Default)
Door bell
8 9 #
To remove The Alarm
To reset the Door Forced Open
warning
Read valid card or Master Code #
To reset the Door Open Too Long
warning
Close the door
or Read valid card or Master Code #