PROGRAMMING OPTIONS CHART
If the pre-programmed default values must be changed
or additional functions are desired, the following options may be programmed.
1. Enter programming mode
Press
99 # (master code)
*
*
2.
Change master code/set main relay time
1 (SEE BELOW)
Press
(Relay Time ) # 1 # (new code)
* (repeat code)
*
Example: Master code of 4321/relay time of 10 seconds
Press
10 # 1 # 4321 * 4321 *
3.
Add/change user code
Press
(user location) # (new code)
* (repeat code)
*
4.
Add/change user code with a different output
Press
(Relay Time) # (user location) # (new code)
*
time on main relay
1 (SEE BELOW)
(repeat code)
*
5.
Delete user codes
Press
(user location) #
* *
6.
Set output 2 time
1 (SEE BELOW)
Press
12 # (Relay Time) # 0 #
* *
7.
Set output 3 time
1 (SEE BELOW)
Press
13 # (Relay Time ) # 0 #
* *
8.
Set output 4 time
1 (SEE BELOW)
Press
14 # (Relay Time ) # 0 #
* *
9.
Set outputs for Remote Triggering Input
Press
17 # (outputs: .ie. 1, 2 or 2, 3 etc.) # 0 #
* *
Note: 0= no outputs
10.
Set outputs for Panic
2 (SEE BELOW)
Press
18 # (outputs: i.e. 1, 2 or 2, 3 etc.) # 0 #
* *
Note 0= no outputs
11.
Turn keypress feedback/audible keypress on
Press
30 # 0 # 1 #
* *
12.
Turn keypress feedback/audible keypress off
Press
30 # 0 # 0 #
* *
13.
Turn yellow LED/sounder on with relay
Press
30 # 1 # 1 #
* *
14.
Turn yellow LED/sounder off with relay
Press
30 # 1 # 0 #
* *
15.
Turn auto entry on
Press
30 # 2 # 1 #
* *
16.
Turn auto entry off
Press
30 # 2 # 0 #
* *
17.
Turn keypad active output on
3 (SEE BELOW)
Press
43 # 0 # 99 #
* *
18.
Turn keypad active off
Press
43 # 0 # 00 #
* *
19.
Erase keypad memory/reset defaults
Press
46 # 00000 # 00000 #
* *
20.
Energize selected output(s) with a user code
4
Press
59 # (outputs: i.e. 1, 2 or 2, 3 etc.) #
(user location) # (new code) * (repeat code) *
Example: User 2; code of 4321*; energize outputs 2 & 3
Press
59 # 23 # 02# 4321 * 4321 *
3
NOTES:
1
1
Relay time must always be represented by 2 digits. Example: 5 seconds = 05.
Latching /toggle is accomplished by entering a time of 00
2
2
If selected, panic will operate by pressing the * and # simultaneously.
Panic operates for 1 second and is defaulted to output 4.
3
3
Keypad active is a negative voltage output (sink) available
on terminal (or wire) marked WB (see wiring diagrams for location).
4
4
This feature is not available with the master code.