P/N 1808922 Rev. C
9
Electric Installation
Item Part #
Description
1. 1800418 Solenoid
2. 1800429 Solenoid Cover
3. 1801726 Toggle Switch
4. 1801265 Toggle Switch Plate
5. 1800430 Ring Terminal - 8 Ga. x 1/4"
6. 1801486 Ring Terminal - 8 Ga. x 3/8"
7. 1800417 Circuit Breaker - 60-Amp 12V
8. 1800441 Butt Connector - 18-22 Ga.
A. 1800802 Sheet Metal Screw - #10 x 1"
B. 1800783 Cap Screw - 1/4" x 1 1/2"
L. 1800699 Lock Nut - 1/4"
M. 1800431 Hex Nut - 5/16"
T. 1800784 Flat Washer - 1/4" SAE
U. 1800787 Lock Washer - 5/16"
NOTE:
New electric motor kits include dual-conductor wire. If
not using new electric kit, use existing wire on truck.
STEP 1:
Locate solenoid in sheltered location, such as bat
-
tery box, cab or under cab. Using solenoid as guide,
mark and drill 1/4" holes. Loosely fasten solenoid with
screws
B
, washers
T
and nuts
L
.
1
2
7
3
STEP 2:
Locate circuit breaker near battery. Fasten with
screws
A
and washers
T
.
4
5
6
8
solenoid
drill
1/4"
holes
60a
circuit
breaker
CAUTION
Do not pull dual-strand wires apart. To separate,
cut through insulation between wires carefully with
knife. Pulling wires apart could damage wire insula-
tion and expose wire. This could result in equipment
damage and/or personal injury.
!
NOTE:
Cut wires to length and strip only enough wire insulation
to install ring terminals. Insert bare wire into ring terminals and
crimp securely.
strip
wire
insulation
ring
terminal
crimp
securely
CAUTION
Do not spray electric components with pressure
washer or hose.
!
L
A
T
T
B
U
M
T
A
B
L
T
A
T
Содержание Quick-Flip III 1808912
Страница 1: ...Quick Flip III Electric Conversion 1808912 P N 1808922 Rev C ...
Страница 19: ...P N 1808922 Rev C 16 Notes ...