11.2 Common fault and eliminating methods
work breakdown
Common cause of failure
Solution
pump chamber is not filled with liquid
filling of liquid
No flow or unstable flow
outlet valve is closed
open outlet valve
inlet pipe is closed or blocked
open inlet piping or wash
pump stuck
clean the pump chamber and check
if there is any foreign body entering
medium viscosity is too high to be inhaled
Increase inlet pipe diameter and
shorten pipe length
model of the pump is too small
contact Donjoy
Flow and discharge too
small
wrong direction of motor rotation
Adjust motor steering
transport medium viscosity is too high, poor
liquidity
Increase inlet pipe diameter and
shorten pipe length
too low speed (wrong voltage)
check power supply voltage
according to motor nameplate
hard object in the pump chamber
exclude foreign body
Noise and vibration
Impeller scratches
check impeller clearance and adjust
suction line resistance is too large
Increase inlet pipe diameter and
shorten pipe length
pipe weight and pressure act directly on the
pump
add pipeline support to eliminate
resonance
Sudden increase in shaft
power
too high viscosity of conveying medium
contact Donjoy
bearing or motor damage
check and repair
Damaged mechanical seal(wear)
change mechanical seal
Mechanical seal leakage
mechanical seal dry rotation, medium
temperature is too high
Double mechanical seals are
recommended
corrosion of mechanical seal material
contact Donjoy
flushing circulation line is blocked cause dry
rotate
check and repair