7-10. Control of R-sensor OFF Point
INPUT
CONTROL OBJECT
●
”J1”,”J2” On Main PCB
●
Control Resistance of R sensor OFF Point
A. LOW COOLING OPTION
- When the refrigeration of refrigerator is poor or weak though Fan and COMP are working continuously,
the following actions are recommended for service.
●
Resistance (R47) : Default resistance (31.4Kohms)
●
Resistance (R45) : Cut the “J1” off to reduce basic resistance by 1.5
°
C. (2KΩ up)
●
Resistance (R42) : Cut the “J2” off additionally to reduce basic resistance by 1.5
°
C. (total 4KΩ up)
R47 = R-SENSOR OFF point
R47 + R45 = R-SENSOR OFF point - 1.5
°
C
R47 + R45 + R42 = R-SENSOR OFF point - 3
°
C
22
R-SENSOR
J2
R47(31.4K)
R45(2K)
R42(2K)
J1