![Donaldson UFM-T100H Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/donaldson/ufm-t100h/ufm-t100h_manual_2520614006.webp)
6
US
Functional elements
For your saftey
A
Cover screws Pozidrive 1;
0.74 ft lbf
B
Cover with heater
C
LED
Light On:
On
Light Flashing: Error
D
Test button
E
Cover
F
Fixing screw
G
Ribbon cable
H
Inlet opening
G
1” ISO 228/1
I
Potential-free contact 3,4
J
Power supply , contact 1,2
Attention 24VDC-Version !
Contact 1
+24VDC
Contact 2
0 VDC
K
Earthing connection, PE
L
Key area
2"
M
M16x1,5
screw connection for potential-
free contact 3,4 (option)
N
M16x1,5
screw connection for
power supply 1,2
O
Collecting area seal
P
Condensate collecting area
Q
Membrane
R
Drain plug
S
Replacement parts set
(without adapter T)
T
Membrane adapter
U
Fastening holes for attachement to a
console (self-tapping screws,
DIN7990; D5,5mm; Lmax 20mm)
V
Screws (
4
x) long
Torx
®
;
19.2 ft lbf
W
Screws (2x) short
Torx
®
;
19.2 ft lbf
X
Drain and drain adapter
You as operator / user of the unit should
make yourself familiar with the function,
installation and start-up of the unit
through these operation instructions.
It is essential that you follow these
safety notes and this information in
order to ensure trouble-free operation of
the unit.
All safety information in always intended
to ensure your personal safety
The pressure and temperature of the
medium must match witch the details
given on type plate of the unit.
Installation work may only be carried
out by trained and experienced
specialists.
Disconnect the power supply when
carrying out electrical work.
Wear protective glasses, when
working with media under pressure.
Risk of explosion ! It is not permitted
to use this unit in areas at risk of
explosion or with explosive or
inflammable media.
It is forbidden to carry out any kind of
work on the pressure vessels and
piping this covering welding,
constructional changes, installation
work, etc. Breaking this rule means
extreme danger for you.
Clean the piping before carrying out
the installation work.
Make a visual check before the initial
start-up. There must be no external
damage visible.
Depressurize the system before
carrying out the installation work.
Use the unit for appropriate purpose!