Problem
Probable Cause
Remedy
Fan does not start
Not wired correctly.
Check and correct internal motor wiring for
proper connections for your voltage (see
Wiring Diagram)
Proper wire size not used for
motor
Rewire per national and local electric codes
for proper wire size.
Fan set starts, but
does not keep
running
Incorrect overload protection
is installed
Check for proper motor overload protection.
Reset or replace if needed for proper value.
Dust collector doors are
open or not closed tight
Tighten doors securely.
Hopper open to atmosphere
Install dust bin under hopper and seal the
access door securely.
Damper valve not adjusted
properly
Check airflow in ducting for proper
requirements. Adjust the damper valve until
the proper airflow is achieved. Do not
attempt to run without inlet ducting
attached.
Electrical circuit fuses
Check if the supply circuit has sufficient
power to run all equipment.
Excessive
noise/vibration of the
fan
If this
happens, it
should be
rectified at
once
Dust deposit on the blades
Clean the blades.
Worn blades
The fan wheel has to be replaced.
Worn bearings
The bearings have to be replaced.
Dust emission
Filter elements installed
improperly
Check that gaskets on the filter element(s)
are firmly pressed to the tube sheet (the
wing nuts of the filter elements should be
fully tightened by hand).
Filter element damage,
dents in the end caps,
gasket damage or holes in
pleated media
Replace the filter elements.
Doors not airtight
Tighten doors securely and check sealing.