Donaldson BOFA FireBOX GA Скачать руководство пользователя страница 7

Before installation

 

 

 
 
 
 

 
Unit placement

 

 
Before installation, check the unit for damage. 
All packaging must be removed before the unit is connected 
to the power supply.  

Please read all instructions in this manual before using 
this extractor. 

 

1.

 

Move the unit to the location where it is going to be 

installed and remove the outer packaging. 

This unit 

should be installed in a well-ventilated area.

 

 
2. Open the front door and check the filter is located 
correctly. (remove any transit foam, if fitted) 

 
 
 
 
 
 
 
 

 

 
 
 

 

 

 

 

 

Caution 
 

Due to the weight of the extractor suitable lifting equipment 
should be used and with regard to appropriate safety 
precautions. (See Appendix for product weight details) 
 
 

Ensure that 500 mm space is available around any vented 
panels on the unit to ensure adequate airflow. 
 
3. With the unit in position lock the 2 front castors. 

 

 

 

Caution 

Do not block or cover any cooling vents on the unit, 
as this severely restricts airflow and may cause 

damage to the unit. 

Caution 

Under no circumstances should the exhaust 
outlet/s be covered as this will restrict the airflow 

and cause overheating. 
 
4. Check the filters are located in their correct position 
before closing the door and securing the door latches. 

 

 

 

 

 

 

 

 

 

 

 

Unlocked Position 

Locked Position 

01 

Содержание BOFA FireBOX GA

Страница 1: ...V1 Oct 18 FireBOX GA User Manual USER MANUAL...

Страница 2: ...re methods Connecting to power supply 4 01 Turning extraction unit on Setting trip point 5 01 02 Important safety notes Safety labels 2 01 02 Cleaning the unit Pre filter replacement 6 01 Consumable s...

Страница 3: ...Overview 01 1 Fire Extinguisher Pressure gauge Beacon On Off Switch Pre Filter Valve Test Reset buttons Digital Temperature display...

Страница 4: ...verview 02 1 Mains out to extractor Mains In External Valve connector Fire extinguisher housing Fire Extinguisher outlet Pressure Relief valve Pressure gauge for trigger tube Air inlet Air outlet Valv...

Страница 5: ...ules and regulations for work on live components are always observed Important To reduce the risk of fire electric shock or injury 1 Always isolate the system from the mains power supply before removi...

Страница 6: ...used in a manner not specified by the manufacturer the protection provided by the equipment maybe compromised Fire Risk Warning In the very rare event that a burning ember or spark is drawn into the...

Страница 7: ...of the extractor suitable lifting equipment should be used and with regard to appropriate safety precautions See Appendix for product weight details Ensure that 500 mm space is available around any ve...

Страница 8: ...emove the connector from the other side of the flexible hose Cut the flexible hose to suit the distance back to the extractor connection and connect onto the extractor inlet Purge air should be kept t...

Страница 9: ...f this manual when selecting the power supply outlet Consideration must also be given to the electrical load that will be connected to the FireBOX from the extraction unit ensure the power supply is s...

Страница 10: ...he small standpipe located inside the extractor inlet 2 Run the sensor tube through the flexible hose and cut to length 3 On the FireBOX there may be a black rubber cover over the small sensor standpi...

Страница 11: ...portant that the controller is adjusted 100 C higher than the airflow temperature when running in normal conditions When the controller reaches the set temperature the power to the extractor will be s...

Страница 12: ...ate the test Green Button Reset Valves Pressing this button will open the valves Press and hold for 1 second and check the Valves are in the open position before operation In the event of initial 10 d...

Страница 13: ...sher is added to your fire extinguisher annual servicing All fire equipment must be suitably maintained by a competent person in line with your countries legal requirements If you are in any doubt ple...

Страница 14: ...unit and open the door 3 The Pre filter is located inside using the handle on the front of the filter pull it out of the unit 4 Once removed it is recommend that the used filters are bagged and seale...

Страница 15: ...ineer Filter disposal The filters are manufactured from non toxic materials Filters are not re usable cleaning used filters is not recommended The method of disposal of the used filters depends on the...

Страница 16: ...to 31o C Max 50 RH at 40o C Shipping Instructions Dangerous Goods Classification The Firebox product category contains components which means that it has been classified as a Dangerous good under the...

Страница 17: ...Creekmoor industrial Estate Poole Dorset BH17 7DU UK Phone 44 0 1202 699444 BOFA Americas 303 S Madison Street Staunton Illnois 62088 USA Phone 001 618 205 5007 BOFA International GmbH Sudring 62 D 21...

Отзывы: