This manual contains specific precautions related to worker safety. The hazard alert image denotes 
safety related instructions and warnings in this manual. DO NOT operate or perform maintenance on this 
collector until you have read and understood the instruction and warnings contained within this manual.

Torit Backward Inclined Fan 

TBI-3 to 30 (60 and 50 Cycle)

Installation and Operation Manual

Installation, Operation, and Service Information

IOM AD3934101 (ENG)

Revision 2

English 

Master Language

Содержание TBI 10

Страница 1: ...manual DO NOT operate or perform maintenance on this collector until you have read and understood the instruction and warnings contained within this manual Torit Backward Inclined Fan TBI 3 to 30 60...

Страница 2: ...ipment This manual has been supplied to assist with the installation operation and maintenance for the collector purchased Please read the manual before installing operating or performing maintenance...

Страница 3: ...ts 7 Fan With Inlet Spool Piece Mounted to Clean Air Outlet Without Weld Nuts 7 Motor Drain Hole Orientation Side Mount Fans 8 Fan with Inlet Spool Piece Mounted to Clean Air Outlet with Adapter 8 Fan...

Страница 4: ...or materials remains the responsibility of the process owner operator Donaldson may provide referrals to consultants suppliers of equipment or services related to the detection and or mitigation of s...

Страница 5: ...ector to be filtered Cleaned air exits the collector via the outlet of the TBI Fan Inspection on Arrival 1 Inspect equipment and parts on delivery 2 Report any damage to the delivery carrier 3 Request...

Страница 6: ...odically Rotate the wheel by hand every two weeks to redistribute grease on motor bearing parts Installation Codes and Procedures Codes may regulate recirculating filtered air in your facility Consult...

Страница 7: ...View the fan rotation through the back of the motor To reverse rotation three phase power supply switch any two leads on the output side of the motor starter Do not interchange a power lead with the...

Страница 8: ...he motor manufacturer TBI fans are dynamically balanced and tested at operating speeds to check for conformance to vibration limits All fans must be adequately supported for smooth operation Safe oper...

Страница 9: ...n TBI 3 through 30 6 Fan Installation motor lifting points lifting points fan wheel inlet cone fan housing sealant sealant spool not supplied on all fan assemblies dust collector clean air outlet refe...

Страница 10: ...weld nuts on the clean air outlet 1 Apply the sealer furnished in the installation hardware kit around clean air outlet opening of the collector Sealer should be applied in a Figure 8 type pattern aro...

Страница 11: ...erior of the fan as well Turn the wheel by hand to check for binding 4 Complete the electrical connections in accordance with NEC code and state and local codes Bump the starter to make sure the motor...

Страница 12: ...inal position later in Step 6 3 Remove the motor wheel assembly from the fan housing Do not remove the wheel from the motor shaft 4 Position the fan housing onto the collector surface with the fan inl...

Страница 13: ...the silencer pack drawings a Align the support bracket to the underside of the silencer flush with the cabinet wall and mark the drill locations b Drill pilot holes with a 0 339 in bit c Secure bracke...

Страница 14: ...termined by the severity of the application and local conditions Strict adherence to an inspection schedule is essential When installing a new wheel or cone the proper wheel to drive side plate must b...

Страница 15: ...00 hours In severe dirt and abrasive dust conditions grease every 2750 hours Under extreme conditions such as an environment with iron dust grease every 550 hours Wheel Balance Airstreams containing p...

Страница 16: ...t adjusted properly Check airflow in duct Adjust damper control until proper airflow is achieved and the blower motor s amp draw is within the manufacturer s rated amps Electrical circuit overload Che...

Страница 17: ...tion or installed backwards on shaft Proper fan rotation is clockwise from the top of the fan The fan can be viewed through the back of the motor Poor system design closed dampers air leaks or clogged...

Страница 18: ...__________________________________________________________ Dust Properties Kst_______________Pmax______________MIE____________MEC_________________ Accessories__________________________________________...

Страница 19: ...manufactured by a third party Third Party Product may constitute contain be contained in incorporated into attached to or packaged together with the goods Buyer agrees that a Third Party Products are...

Страница 20: ...mportant Notice Many factors beyond the control of Donaldson can affect the use and performance of Donaldson products in a particular application including the conditions under which the product is us...