Downflo Workstation, DWST 4-1 to 6-4
A6
Acoustic Hard Sided Booth Assembly
Note: Use M8 x 45 mm bolts to fasten the side rail channels.
Use M8 x 35 mm bolts to fasten the top support channels.
Use M8 x 20 mm bolts for the remainder of the assembly.
1. Fasten the module side angles to the right and left side of the assembled power modules.
2. Fasten the top panel angle to the top front of each power module.
3. Assemble two booth panels and a side panel angle to form a wall collector.
4. Attach wall to the outside of the power module side angle.
5.
Fasten the side-rail channels to the wall using M8 x 45 mm long bolts, flat washers, and hex nuts.
Note: The side-rail channel with four bolt holes fits on the outside bottom of the walls and the side-rail channel with three
bolt holes fits on the inside of the walls about midway up. Do not fasten the inside channel until the acoustic panels
have been installed.
6. Bolt the gussets to the right and left support legs and fasten the support legs to the edge of the corresponding walls.
7. Bolt the top support channel to the gussets.
Note: The DWST-2 requires one top support channel. DWST-3 and DWST-4 require two top support channels. When
assembling the DWST-3 or DWST-4, bolt the two top support channels and the top support tie-in together and then
bolt to the gussets.
Roof panels are not intended as platforms. Personnel should use ladders or other appropriate equipment to avoid
risk of personal injury and/or property damage.
8. Install and bolt the booth roof panels in place.
Note: Temporary roof support is required on larger booth assemblies. The top panel angles and the top support channels
support the roof panels.
9. Attach the splice plate to the top panel angles with the roof panels.
10.
Install the acoustic panels to the power modules, booth roof, and walls.
11. Secure acoustic panels with nylon Christmas Tree
™
clips supplied.
12.
Install flexible protective caps over exposed end of Christmas Tree clips.
13.
Tuck the edges of the booth acoustic panels into the return flanges of the booth panels.
14.
See light fixture mounting and wiring.
15. Anchor last holes from power module.