Ash Compressor Drawer
20
EN
12
OPERATING AND MAINTENANCE INSTRUCTIONS
The ash compressor
(19)
compressor drawer must be emptied regularly, in accordance with power
requirements and pellet quality.
The boiler maintenance requires performing an annual cleaning of the compressor casing
(15).
12.1
Activating the empty ash compressor warning
The
BioClass NG
includes the option “Empty ash compresor warning”. This function warns us that
the ash drawer is full and needs emptying. In the
"Ashtray status"
parameter in the
"User Menu"
is
displayed its status. When full, a warning is activated, indicating the need for emptying.
By default, this function is activated and set to values for operating with manual ashtray. These
values must be updated when you install the compressor ashtray from the table below and
following the instructions in the paragraph
"Ashtray empty notice"
on the boiler manual.
Boiler model
Kg Pellets
Bioclass NG 10
2000 Kg.
Bioclass NG 16
2200 Kg.
Bioclass NG 25
2800 Kg.
Bioclass NG 43
4000 Kg.
NOTE: The ashtray must be emptied every time
a new value of this parameter is set.
12.2
Safety warnings
For
safe handling
of the ash drawer, you should take the necessary safety precautions and wear
suitable clothing to protect against possible injury. Pay special attention to the following
recommendations:
-
Switch off the boiler or ensure it is on pause
before taking out the ash drawer. If you take out
the ash drawer with the boiler on pause, make sure you replace it before switching on the boiler
again. It is recommended to take out the ash drawer when no flame is detected in the burner.
- It is recommended to wear insulating
thermal gloves
to protect your hands from any burns
from hot parts of the drawer.
- It is recommended you wear a
protective mask
to avoid breathing in any ash particles,
particularly in the case of people with allergies or any type of respiratory problems, who should
always wear a mask when carrying out ash removal.
- As the ash to be removed from the drawer may be burning or glowing, special precautions
should be taken with regard to the type of container it is emptied into. A metal container is
recommended, or the
ash should be totally extinguished
on handling, using water or another
extinguishing agent.
- The ash drawer must be emptied with the boiler switched off.
Never touch the screwas
it could
trap your hand.
DOMUSA
shall not be liable for any injury or damage caused to people, animals or property as a result
of incorrect handling of the ash drawer or the ash itself.
IMPORTANT: The ash drawer must only be cleaned when the boiler is switched off or on pause.