11
HDEE 45/90 - 10/15 - 180:
HDEE
Pressure Drop
Pressure Drop
HDEEM 45/90 - 10/15 - 180:
HDEEM 210:
Pressure Drop
Pressure Drop
13
TECHNICAL CHARACTERISTICS
HDEE HDEEM
MODEL
45/90 10/15 180 210 45/90
10/15 180 210
Power
kW 4.5-9 10.5-15
18 21 4.5-9 10.5-15 18 21
Main supply voltage
V
230 V~
230 V 3~
400 V 3N~
400 V 3N~
230 V~
230 V 3~
400 V 3N~
400 V 3N~
Element type
kW
6x1.5
6x2.5
6x3 6x1.75 6x1.5
6x2.5
6x3 6x1.75
Number of elements
-
1
1
1
2
1
1
1
2
Water pressure drop
mH
2
O 0.02 0.08 0.1 0.2 0.30 0.38 0.02 0.08 0,11 0,22 0,31 0,46
Resistance value of heating element
Ω
35.2
21.1 17.6 30.2
35.2
21.1 17.6 30.2
Expansion vessel volume
Litres
7.5
7.5
Maximum operating pressure
bar
3
3
Minimum operating pressure
bar
0.6
0.6
Maximum operating temperature
ºC
90
90
Maximum safety temperature
ºC
110
110
Output
3/4" M
1" F
Heating connection
Return
1" F
3/4" M
Height mm
760 640
Width mm
450 450
Depth mm
330 330
Weight Kg
51 43