Selecting the DHW setpoint temperature in the solar hot water tank
The temperature of the DHW in the solar hot water tank is selected by using the MODE touch
button to browse to the
"Solar hot water tank DHW setpoint temperature"
viewing option. When
this option appears on the display, select the desired temperature by touching the "
+
" and "
-
"
symbols to increase or decrease the temperature. The DHW setpoint temperature range that may
be selected for the solar hot water tank is 10 - 80ºC.
10.4
Selecting the underfloor heating flow setpoint temperature (with SRSC2/EV kit option)
If the boiler is supplied with an optional SRS2/EV underfloor heating kit integrated, the desired flow
temperature of the installation can be selected using the touch button as shown in the figure
above. To select the desired temperature, touch the "
+
" or "
-
" symbols to increase or decrease the
temperature. When the temperature has been selected, the display will return to standby mode
after a few seconds.
The installation flow setpoint temperature can also be selected by using the MODE touch button to
browse to the “
underfloor heating installation flow setpoint
" display option. When this option
appears on the display, touch the "+ /-" symbols to select the desired temperature.
If you wish to disable the underfloor heating circuit function, select the setpoint value "
OFF
" by
touching the "-" symbol until this value appears on the display.
The flow setpoint temperature range permitted is OFF and 0 - 45ºC. To obtain optimum
performance from the underfloor heating system installed, we recommend selecting a setpoint
temperature of 25 - 35 ºC, providing this is permitted by the heating system installed and the
insulation in your home.