3.6
Installing the SRFM2/EV Underfloor Heating Kit (Optional)
The procedure for suitably connecting the SRFM2/EV Underfloor Heating Kit to the
Evolution EV
HFM
boiler is as follows:
-
Unplug the boiler from the mains.
- Connect a flow temperature sensor (supplied with the kit) to sensor terminal strip
J3
(terminals
15 and 16), first removing the resistance (
Rr
) supplied by default (see “Electrical Connection
Diagram").
- Fit the temperature sensor bulb according to the instructions enclosed with the kit.
- Connect the heating pump to supply terminal strip
J2
on the circuit 1 pump connection (pump
BC
1
; terminals N and 7) (see “Electrical Connection Diagram").
- Connect the pump´s PWM
C
cable to sensor terminal strip
J3
(terminals 13 and 14) (see
“Electrical Connection Diagram").
- Connect the 3-way mixer valve motor to supply terminal strip
J2
(terminals N, 8 (+) and 9 (-))
(see “Electrical Connection Diagram").
For correct hydraulic installation, carefully follow the assembly and connection instructions
enclosed with the SRFM2/EV kit.
3.7
Installing heating circuit 2 (Optional)
All the models in the
Evolution
range of boilers are supplied with a circulation pump connected to
heating circuit 1 (BC
1
). In addition to this circuit, all the models are designed to control a second
heating circulation pump in a second heating circuit (circuit 2, BC
2
).
The hydraulic installation of heating circuit 2 should be made using the optional flow circuit (IC') on
the rear of the boiler (see "Diagrams and Measurements"). If there is an SRFM2/EV underfloor
heating kit connected to the optional flow IC', heating circuit 2 should be connected at the
additional sockets provided in the kit (on the boiler T-connectors).
The circulation pump installed in heating circuit 2 must be electrically connected between
terminals N and 6 on the supply connector block
J2
(see "Connection Diagram").
Содержание evolution ev 25 hac
Страница 1: ...INSTALLATION AND OPERATING INSTRUCTIONS EVOLUTION EV HFM ER 0170 1996 CGM 04 392 ...
Страница 8: ...Evolution EV HFM 6 ...
Страница 43: ...41 Boiler 1 2 3 4 24 6 7 8 9 7 11 12 13 14 15 16 17 18 19 21 20 22 23 ...
Страница 46: ...Evolution EV HFM 44 NOTES ...
Страница 47: ...45 NOTES ...