DOMUSA TEKNIK BT DUO HE HE 180/60 Скачать руководство пользователя страница 2

Thank you for choosing a 

DOMUSA TEKNIK

 product. From the range of 

DOMUSA TEKNIK 

products you have chosen a 

BT DUO HE,

 a stainless-

steel tank for the production of domestic hot water (DHW) combined with 
a primary buffer, which, along with a heat pump of the 

DUAL CLIMA

 line, 

is able to provide the level of comfort suitable for your home and allows 
you to enjoy a production of balanced and economical hot water. 

This document constitutes an essential part of the product and must be 
delivered to the end user. It is advisable to carefully read the warnings and 
advice contained in this manual, as they provide important information 
regarding the safety of the installation, as well as use and maintenance. 

The installation of these tanks should be carried out only by qualified 
personnel, in accordance with the regulations in force and following the 
manufacturer’s instructions. 

Both the start-up and any maintenance operation of these tanks should be 

carried out only by the Technical Assistance Services authorised by 

DOMUSA TEKNIK

Incorrect installation of these tanks may cause damage to people, animals 
and materials, for which the manufacturer shall not be held liable 

Содержание BT DUO HE HE 180/60

Страница 1: ...INSTALLATION AND OPERATING INSTRUCTIONS BT DUO HE HE 180 60 ...

Страница 2: ...vered to the end user It is advisable to carefully read the warnings and advice contained in this manual as they provide important information regarding the safety of the installation as well as use and maintenance The installation of these tanks should be carried out only by qualified personnel in accordance with the regulations in force and following the manufacturer s instructions Both the star...

Страница 3: ...ION INSTRUCTIONS 4 3 1 HYDRAULIC INSTALLATION 4 3 2 LOCATION 4 3 3 EQUIPMENT OPTIONS 4 3 3 1 CATHODIC PROTECTION 5 3 3 2 SANIT S HIDRAULIC KIT 5 3 3 3 ELECTRICAL HEATER 5 4 TANK DRAINAGE 5 4 1 PRIMARY CIRCUIT DRAINAGE 5 4 2 DHW TANK DRAINAGE 5 5 MAINTENANCE 6 6 START UP 6 7 EQUIPMENT DELIVERY 6 8 TECHNICAL DATA 7 9 SPARE PARTS 8 ...

Страница 4: ...n the tank which should be compatible with public hygiene standards and must not be toxic DOMUSA TEKNIK recommends the use of propylene glycol Please contact the manufacturer of the product before use For long periods of stoppage of the installation all water in the tank should be emptied 1 2 Water Characteristics The domestic water should comply with the characteristics defined in the Technical C...

Страница 5: ... 260 395 1720 R E1 R E2 BT DUO HE 180 60 Domestic cold water inlet ES 3 4 M Domestic hot water outlet SS 3 4 M Primary inlet EP 1 H Primary outlet SP 1 H Optional DHW electrical heater R E1 1 1 4 H Optional Heating electrical heater R E2 1 1 4 H Buffer outlet A 1 H Buffer inlet B 1 H Air vent socket P 3 8 H ...

Страница 6: ...with a safety valve calibrated to a maximum of 0 3 MPa 3 bar Place dielectric sleeves in the connections of the secondary circuit When the cold water pressure is higher than the design pressure of the appliance a calibrated pressure reducer must be installed at a value not higher than the design pressure To avoid heat losses through the hot water pipe in the tank installation an anti thermosiphon ...

Страница 7: ...e two sockets E1 and E2 to connect the two electrical heaters one for DHW and one for the heating circuit DOMUSA TEKNIK supplies three 1 5 2 5 or 3 5 kW electrical heaters as an option For installation please read carefully the installation instructions supplied with them 4 TANK DRAINAGE 4 1 Primary circuit drainage For the correct drainage of the BT DUO HE tank it is advisable to install a cut of...

Страница 8: ...perly It is recommended that the user periodically check the pressure level and temperature of the tank as well as the status of valves fittings and accessories 6 START UP In order to valid the guarantee the heat pump must be started up by personnel authorized by DOMUSA TEKNIK Before beginning the start up process check that The installation must be filled with water and well vented The air vent v...

Страница 9: ...r standing DHW tank volume 180 Primary buffer volume L 60 Max DHW temperature ºC 70 Max DHW working pressure MPa bar 0 7 7 Max primary temperature ºC 85 Max primary working pressure MPa bar 0 3 3 Dry weight Kg 101 Wet weight Kg 341 Exchange surface m2 3 2 ...

Страница 10: ...CACU000038 Cover 4 CTOR000080 M8 washer 5 6 SCHA000746 COTR000006 Elliptic covers holder O ring 7 CFOV000034 Manual air vent valve 8 CFER000083 Compression gland 9 SCON001569 Elliptic cover 10 SOPE000031 Sensor holder sheath 11 CFER000086 1 black trim 12 CFER000184 Compression gland 13 SCOB012550 Sensor holder sheath 14 CFER000087 1 black trim ...

Страница 11: ...9 NOTES ...

Страница 12: ...San Esteban s n 20730 AZPEITIA 20737 RÉGIL GUipuzcoa Tel 34 943 813 899 www domusateknik com DOMUSA TEKNIK reserves the right to make modifications of any kind to its product characteristics without prior notice CDOC001800 CDOC001800 14 11 22 ...