LAGO FB OT+ REMOTE CONTROL (OPTIONAL)
A remote control (LAGO FB OT+) can optionally be supplied together with the
Avanttia
boiler. This
remote control can be used to fully operate the boiler from anywhere in the room in which it is
installed. The LAGO FB OT+ remote control governs the parameters of heating circuit Nº 1 and the
installation’s domestic hot water production.
This remote control allows the hours of home comfort to be programmed for heating circuit Nº 1,
adjusting the installation to the particular requirements of the home by measuring the room
temperature and consequently adapting the installation temperature. The remote control can also be
used to adjust the hot water and heating set point temperatures at any time, and for viewing the
different boiler operation parameters. It also warns of any functioning anomalies affecting the boiler.
The LAGO FB OT+ remote control may optionally be connected to an external sensor, for measuring
the outside temperature. With this option installed, the remote control can adjust the home comfort
level (circuit Nº 1) according to the weather conditions at each particular time, optimising fuel
consumption and heating comfort in the home.
The LAGO FB OT+ remote control takes over the control of the boiler when it is connected to it. The
different selectable boiler temperatures must be modified using the remote control. It is easy to install,
only requiring 2 wires for communication between the boiler and the LAGO FB OT+ control. It is
connected to the boiler by connecting the two wires on terminal strip
J6
(see “Electrical Connection
Diagram”). For correct installation and functioning, carefully read the instructions enclosed with the
remote control.
The following sections contain a general explanation of the different operating modes and options of
the LAGO FB OT+ remote control.
NOTE: The "AF outdoor temperature sensor" indicated in the instructions manual of remote
controller is not compatible with the boiler, so it is compulsory the use of "EVT outdoor
sensor" (provided within the boiler) to measure the outdoor temperature.
7.1
Functioning without an outdoor sensor
Conventional heating installation (direct circuit)
The maximum temperature for heating circuit Nº 1, the heating times and the desired room
temperatures can be selected on the remote control. The LAGO FB OT+ remote control will
calculate the boiler temperature required at each particular time, depending on the temperature
of the room, and it will activate or disable the heating mode of circuit Nº 1 depending on the
heating times and room temperatures programmed.
Instalation of heating circuit Nº 2 (optional)
If the boiler is supplied with an second heating circuit, this circuit is adjusted and controlled via
the boiler control panel (see
"Functioning of heating circuit Nº 2 (optional)"
).