3.0 INSTALLATION

3.1 Dimensions

A

D

B

C

ØE

Front View

Side View

Model

D-DMEV100

D-DMEV150

A

164

218

B

70

97

C

46

52

D

116

149

ØE

99

148

Weight

0,6

1,2

Dimensions

3.2 Installation Preparation

10 

11 

D-DMEV100 = ø99mm

D-DMEV150 = ø149mm

Ø

12 

13 

3.3 Surface Cable Installation

4xø5mm

8A

14 

9A

15 

671982  

|  

SepTemBer 2021

pAGe 4

Содержание D-DMEV

Страница 1: ...etc If any abnormalities in operation are detected disconnect the device from the mains supply and contact a qualified technician immediately Use original spare parts only for repairs The electrical system to which the device is connected must comply with regulations Before connecting the product to the power supply or the power outlet ensure that The data plate voltage and frequency corresponds t...

Страница 2: ...he appropriate window kit which is not included Attention do not mount the product on the window without this kit 1 1 Hazard Symbols REFER TO INSTRUCTION MANUAL Read and understand the installation and maintenance manual before installing operating or maintaining this product 1 2 Important Information This manual contains important information on the safe and appropriate assembly transport commiss...

Страница 3: ...cy aerodynamic fan with winglet blades to optimise quietness and efficiency Single phase EC Brushless motor with integral thermal protection Motor mounted on high quality ball bearings The fan is double insulated no earth connection is required Trickle speed selectable during installation Option to boost from trickle or from off through LS connection Installation type selection available through w...

Страница 4: ...iew Model D DMEV100 D DMEV150 A 164 218 B 70 97 C 46 52 D 116 149 ØE 99 148 Weight 0 6 1 2 Dimensions 7 3 2 Installation Preparation 8 9 10 11 D DMEV100 ø99mm D DMEV150 ø149mm Ø 12 13 3 3 Surface Cable Installation 4xø5mm 8A 14 9A 15 671982 September 2021 PAGE 4 ...

Страница 5: ...1 5 mm2 3 x 0 5 1 5 mm2 HT 3 x 0 5 1 5 mm2 4 x 0 5 1 5 mm2 3 6 Wiring Diagram Wiring 24 3 7 Installation Type Setting Installation type can be selected using JUMPER 1 between the following options through wall or ducted Section 3 9 3 8 Trickle Speed Setting Trickle speed can be selected using JUMPER Section 3 9 671982 September 2021 PAGE 5 ...

Страница 6: ...light switch Figure 24 Trickle speed can be set to off Section 3 9 To deactivate the humidistat function turn the trimmer HY completely clockwise Automatic humidistat operation when the percentage of Relative Humidity exceeds the settable threshold fan speed automatically increases to comfort boost speed intermediate between the selected trickle speed and the boost speed When the percentage of Rel...

Страница 7: ...components can be segregated into mixed plastic and widely recycled Cardboard packaging wood and other paper components can be largely recycled or fully processed in energy from waste centres Filter Disposal Cardboard framed filters should be fully processed in energy from waste centres contact your local civic amenity site household waste recycling centre regarding metal wire framed filters Remai...

Страница 8: ...sions of equipment and the right is reserved to make such changes without prior notice 671982 September 2021 PAGE 8 Domus Ventilation Block C Van Court Caerphilly CF83 3ED United Kingdom Email vent info domusventilation co uk Tel 03443 715 523 www domusventilation co uk Technical or commercial considerations may from time to time make it necessary to alter the design performance and dimensions of ...

Отзывы: