40
When you need to replace the electrical fuse, please ensure that
electrical connection is made as follows:
• Phase (to live terminal) brown cable
• Blue cable to neutral terminal
• Yellow-green cable to earth terminal
Oven disconnecting switches must be in an accessible place for final
user while oven is in its place.
Power supply cable (plug in cable) mustn't touch hot parts of the appliance.
If supply cord (plug in cable) is damaged, this cord must be replaced
by the importer or its service agent or an equally competent personnel to
prevent a hazardous situation.
CONTROL PANEL
Adjustment can be made only when button is popped for models with
pop-up button.
Make sure that button is popped by pressing on the
button as shown in the figure at left side.
Function Button
Mechanical Timer
Thermostat
Function Button
Digital Timer
Thermostat
Figure 6
GB
Содержание DO 82 M NT BK
Страница 11: ...11 560 600 35 500 30 30 555 545 595 595 565 22 Şekil 3 TR ...
Страница 12: ...12 590 550 560 35 500 30 30 Şekil 4 TR ...
Страница 37: ...37 560 600 35 500 30 30 555 545 595 595 565 22 Figure 3 GB ...
Страница 38: ...38 590 550 560 35 500 30 30 Figure 4 GB ...