Controller External Connections
Item
Details
Print Head Connectors:
Gx-IC7: 2 x High-Density D-Sub, 15-Way, Female
Gx-IC10: 4 x High-Density D-Sub, 15-Way, Female
Gx-OEM: 4 x High-Density D-Sub, 15-Way, Female
Encoder Connectors:
Gx-IC7: 1 x D-Sub, 9-Way, Female
Gx-IC10: 2 x D-Sub, 9-Way, Female
Gx-OEM: 2 x D-Sub, 9-Way, Female
I/O Connectors:
(Gx-IC7)
2 x D-Sub, 15-Way, Female
Each connector includes:
•
1 x Product Detect Sensor Input
•
2 x General Purpose Inputs, Max 24 V DC, 1 A
•
4 x General Purpose Outputs, Max 24 V DC, 30 mA
•
2 x 24 V DC, 300 mA Outputs
•
1 x Ground
I/O Terminal Block 1:
(Gx-IC10/Gx-OEM)
1 x S2C 3.5mm, 28-Way, Terminal Block
•
4 x Product Detect Sensor Inputs
•
6 x General Purpose Inputs, Max 24 V DC, 1 A
•
8 x General Purpose Outputs, Max 24 V DC, 30 mA
•
2 x 24 V DC, 300 mA Outputs
•
2 x Grounds
I/O Terminal Block 2:
(Gx-IC10/Gx-OEM)
1 x S2C 3.5mm, 18-Way, Terminal Block
•
3 x Alarm Outputs, Max 24 V DC, 300 mA
•
4 x General Purpose Inputs, Max 24 V DC, 1 A
•
4 x General Purpose Outputs, Max 24 V DC, 30 mA
•
1 x 24 V DC, 300 mA Output
RS232C:
D-Sub, 9-Way, Male
LAN:
2 x RJ-45
Data Transfer:
2 x USB, Type A
Power Connector:
Gx-IC7: 6 mm DC Power Jack
Gx-IC10: 3-way Plug, Cable Supplied.
Gx-OEM: S2C 3.5 mm, 4-way, Terminal Block
SYSTEM DESCRIPTION
EPT053091 - Issue 5 - 07 May 2021
18
Содержание Gx-OEM
Страница 1: ...Gx Series Product Manual Gx150i Gx350i Gx OEM ...
Страница 61: ...10 Replace side cover and screws End of procedure INSTALLATION EPT053091 Issue 5 07 May 2021 56 ...
Страница 63: ...3 Install the faceplate End of procedure INSTALLATION EPT053091 Issue 5 07 May 2021 58 ...
Страница 65: ...3 Install the faceplate End of procedure INSTALLATION EPT053091 Issue 5 07 May 2021 60 ...
Страница 122: ...The illustration below shows the Setup screen OPERATION 117 EPT053091 Issue 5 07 May 2021 ...
Страница 197: ...EPT053091 Issue 5 07 May 2021 192 ...