Awning Control - Diagnostics Guide

W

ind Speed LEDs 

“ON” LED 

Meaning 

Reaction by Control 

Reaction by User 

SELECTED WIND SPEED 

ON 

ON 

• 

Proper voltage is detected at Control and  Wind Sensor is enabled 

• 

Normal operation of control. 

• 

No user reaction required. 

ALL

 LEDs OFF 

ON 

• 

Wind Sensor has been disabled with the Key  FOB 

• 

Control will retract the awning after 5 seconds, if the awning is  extended when wind sensing is disabled.. 

• 

Control disables the “normal” extension routines for awning 

• 

User can extend awning by pressing and holding the extend button.  Awning will extend for approximately 4 seconds and stop. User can  repeat as necessary to obtain full extension. 

• 

User should re-enable the Wind Sensor whenever possible 

SELECTED WIND SPEED 

BLINKING 

ON 

• 

Wind Sensor has been activated by wind 

• 

Control retracts awning if awning is extended. 

• 

Control monitors for sensor activation during retraction and at awning  closure to determine if activation continues after awning closure. 

• 

Control will reset after awning closure, if sensor activation is no longer  detected. 

• 

User should observe wind conditions before attempting to extend the  awning after any automatic closure. 

• 

User can extend awning as normal (after control resets) 

• 

User should use caution if they choose to disable the wind sensor with  wind present. Disabling the sensor is not recommended here. 

LEDs SEQUENCE ON,  THEN OFF FROM 

TOP

 

DOWN 

ON 

• 

W

et Sensor 

• 

Control retracts awning if awning is extended.

• 

Control monitors for sensor activation during retraction and after 

awning closure to confirm W

et Sensor condition exists.

• 

Control disables the wind sensor

• 

Control disables the “normal” extension routines for awning 

• 

Control will automatically re-enable wind sensor when it determines the  sensor is no longer activated (no longer wet) 

• 

If sensor activation condition is observed for longer than 12 hours, and  awning is extended, then control will retract awning. 

• 

User should observe wind conditions before attempting to extend the  awning after any automatic closure. 

• 

User can extend awning by pressing and holding the extend button.  Awning will extend for approximately 4 seconds and stop. User can  repeat as necessary to obtain full extension. 

• 

User should re-enable the Wind Sensor whenever possible 

SELECTED WIND SPEED  BLINKING (alternating)

 BLINKING  (alternating) 

• 

Sensor fault/ Communication issue between  the Wind Sensor and the Control Box. 

• 

Control retracts awning after 5 seconds if awning is extended when  communication issue is detected. 

• 

Control disables extension of the awning by the user while the wind  sensor is enabled 

• 

Control will reset if communication is re-established. 

• 

User should observe wind conditions before attempting to extend the  awning after any automatic closure.

• 

User can disable wind sensor with Key FOB to extend awning. 

BOTT

OM TWO 

LEDs 

BLINKING 

ON 

• 

Wind Sensor is detecting temperatures  below 32° F 

• 

Control retracts awning if awning is extended when low temperature is  detected. 

• 

Control disallows any extension of the awning until temperature goes  above 32° F

• 

User should observe temperature before attempting to extend awning  again. 

• 

User can disable wind sensor with Key FOB to extend awning. 

OFF 

BLINK 

• 

Power detected by control is less than 10.5  VDC (tolerance is +.5 VDC and -0.0 VDC) 

• 

Control retracts awning if awning is extended when low voltage  situation is detected. 

• 

Control disallows any extension of the awning until proper voltage is  detected. 

• 

User will not be able to extend awning. 

• 

Check voltage at house battery gauge or other gauge as necessary to 

confirm low voltage condition.

• 

If voltage is low

, then start coach engine to charge batteries.

• 

User should contact service center if low battery condition reoccurs. 

OFF 

OFF 

• 

No Power 

• 

No reaction by control 

• 

Awning(s) cannot be operated 

• 

Suggest user to contact service center

• 

Check voltage source at control, correct as necessary 

• 

Check internal fuse at control box. Replace if necessary

.