WeatherPro Awning User’s Guide
6
W
eatherPro
Awning Control - Diagnostics Guide
W
ind Speed LEDs
“ON” LED
Meaning
Reaction by Control
Reaction by User
1
SELECTED WIND SPEED
ON
ON
•
Proper voltage is detected at Control and Wind Sensor is enabled
•
Normal operation of control.
•
No user reaction required.
2
ALL
LEDs OFF
ON
•
Wind Sensor has been disabled with the Key FOB
•
Control will retract the awning after 5 seconds, if the awning is extended when wind sensing is disabled..
•
Control disables the “normal” extension routines for awning
•
User can extend awning by pressing and holding the extend button. Awning will extend for approximately 4 seconds and stop. User can repeat as necessary to obtain full extension.
•
User should re-enable the Wind Sensor whenever possible
3
SELECTED WIND SPEED
BLINKING
ON
•
Wind Sensor has been activated by wind
•
Control retracts awning if awning is extended.
•
Control monitors for sensor activation during retraction and at awning closure to determine if activation continues after awning closure.
•
Control will reset after awning closure, if sensor activation is no longer detected.
•
User should observe wind conditions before attempting to extend the awning after any automatic closure.
•
User can extend awning as normal (after control resets)
•
User should use caution if they choose to disable the wind sensor with wind present. Disabling the sensor is not recommended here.
4
LEDs SEQUENCE ON, THEN OFF FROM
TOP
DOWN
ON
•
W
et Sensor
•
Control retracts awning if awning is extended.
•
Control monitors for sensor activation during retraction and after
awning closure to confirm W
et Sensor condition exists.
•
Control disables the wind sensor
.
•
Control disables the “normal” extension routines for awning
•
Control will automatically re-enable wind sensor when it determines the sensor is no longer activated (no longer wet)
•
If sensor activation condition is observed for longer than 12 hours, and awning is extended, then control will retract awning.
•
User should observe wind conditions before attempting to extend the awning after any automatic closure.
•
User can extend awning by pressing and holding the extend button. Awning will extend for approximately 4 seconds and stop. User can repeat as necessary to obtain full extension.
•
User should re-enable the Wind Sensor whenever possible
5
SELECTED WIND SPEED BLINKING (alternating)
BLINKING (alternating)
•
Sensor fault/ Communication issue between the Wind Sensor and the Control Box.
•
Control retracts awning after 5 seconds if awning is extended when communication issue is detected.
•
Control disables extension of the awning by the user while the wind sensor is enabled
•
Control will reset if communication is re-established.
•
User should observe wind conditions before attempting to extend the awning after any automatic closure.
•
User can disable wind sensor with Key FOB to extend awning.
6
BOTT
OM TWO
LEDs
BLINKING
ON
•
Wind Sensor is detecting temperatures below 32° F
•
Control retracts awning if awning is extended when low temperature is detected.
•
Control disallows any extension of the awning until temperature goes above 32° F
.
•
User should observe temperature before attempting to extend awning again.
•
User can disable wind sensor with Key FOB to extend awning.
7
OFF
BLINK
•
Power detected by control is less than 10.5 VDC (tolerance is +.5 VDC and -0.0 VDC)
•
Control retracts awning if awning is extended when low voltage situation is detected.
•
Control disallows any extension of the awning until proper voltage is detected.
•
User will not be able to extend awning.
•
Check voltage at house battery gauge or other gauge as necessary to
confirm low voltage condition.
•
If voltage is low
, then start coach engine to charge batteries.
•
User should contact service center if low battery condition reoccurs.
8
OFF
OFF
•
No Power
•
No reaction by control
•
Awning(s) cannot be operated
•
Suggest user to contact service center
.
•
Check voltage source at control, correct as necessary
•