EN
Troubleshooting
CombiPower
100
I
NOTE
If you have detailed questions on the
battery specifications
,
please contact the battery manufacturer.
No output voltage, “Inverter”
LED lights up red, display
shows “ENIR TEMP Shut-
down”
Overheating
Check the ventilation grilles
and clean them if necessary
Improve the ventilation
Set up the device somewhere
cooler
No output voltage, “Inverter”
LED lights up red, display
shows “H.S. TEMP Shut-
down”
No output voltage, “Inverter”
LED lights up red, display
shows “BAT. TEMP Shut-
down”
No charging current
Incorrect frequency
Check the configured fre-
quency
No charging current,
“Charger” and “AC Grid”
LEDs are off
No 230 V power
Check the 230 V power sup-
ply
Check the wiring
No charging current, “Alarm”
LED lights up red, display
shows “UV Alert”
Overheating
Switch off the consumer
units.
Let the inverter cool down
and ensure better ventilation
The device constantly
restarts
No connection to the battery
Check the battery wiring
Fault
Cause
Remedy
_CombiPower_IA_DE-IT.book Seite 100 Freitag, 21. Oktober 2011 8:10 20