INSTALLATION GUIDE

On installation of the appliance, the technical and administrative regulations of the 

country in which the vehicle will first be used must be adhered to. Otherwise the 

refrigerator must be installed as described in these instructions. In some OEM appli-

cations it may not be possible for these instructions to be followed exactly. In this case 

an authorised Dometic representative may issue supplementary instruction

In Europe, for example, gas appliances, cable laying, installation of gas 

cylinders, as well as approval and checking for leaks must comply with 

EN 1949 for liquid gas units in vehicles.

Installation

The appliance and its fume extraction shall be installed in such a way as to be acces-

sible for servicing at all times and must be capable of easy removal and installation.

The appliance may only be installed by authorised personnel.

Installation and connection of the appliance must comply with the latest 

technical regulations, as follows:

ŸŸ

The electrical installation must comply with national regulations.

ŸŸ

Technical regulations EN 60335-1, EN 60335-2-24, EN 1648-1 , EN 1648-2

ŸŸ

The gas installation must comply with national regulations.

ŸŸ

Technical regulations EN 1949

ŸŸ

Technical regulations EN 732

ŸŸ

Local and building control department requirements

ŸŸ

The appliance shall be installed in such a way that it is shielded from 

excessive heat radiation.

Excessive heat impairs performance and raises the energy consumption of the 

refrigerator.

Side installation

If the appliance is installed on the same side of the vehicle as the entrance 

door, it is desirable that the door does not cover the refrigerator’s vents. If this cannot

be avoided there must be a gap of at least 25mm between the door and the vents. 

Rear installation

If the refrigerator is mounted at the rear of the vehicle you must ensure the lower grille 

is not covered by the bumper or rear lights. This would be prevent the air from circula-

ting properly and cause problems in warm weather. 

66..00

6.1

6.1.1

Any installation that is not carried out by qualified persons will jeo-

pardize the manufacturer's guarantee.

Air vent grille not

blocked: OK!

6.1.2

An installation that is not carried out by qualified persons causes a

reduction in the cooling capacity and will jeopardize the manufactur-

er's guarantee.

Содержание TYPE C40 RM 7601 L

Страница 1: ...NUAL ABSORPTION REFRIGERATOR for CARAVAN and MOTORHOME EN English OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS RM 7601 L RM 7605 L RM 7651 L RM 7655 L Model number Product number Serial number Ple...

Страница 2: ...conditions the refrigerator cannot guarantee having the temperature needed for food that perishes quickly Foods that perish quickly include all the products with a stipulated use by date and a minimu...

Страница 3: ...panel 13 5 12 Changing the doorhang 14 5 13 Troubleshooting 15 5 14 Maintenance 16 5 15 Product liability 16 5 16 Environmental hints 16 5 17 Disposal 16 5 18 Energy saving tips 16 5 19 Technical dat...

Страница 4: ...cylinder open the windows and leave the room do not switch on anything electrical extinguish naked flames Never open the cooling unit it is under high pressure Work on the gas flue system and electri...

Страница 5: ...ata plate inside the refrigerator Damage in transit After removing the packaging check whether the refrigerator has been damaged during transportation Any damage sustained in transit must be reported...

Страница 6: ...is selected by means of energy selector switch A Energy selector switch A has four settings AC mains power DC 12V Gas liquid gas OFF Appliances with automatic energy selection have the additional sett...

Страница 7: ...emperature in the main refrige rator compartment A 1 Set energy selector switch A to 12V Operating display C 12V lights green Appliance is in function 2 Use rotary switch B to regulate the temperature...

Страница 8: ...gnition the display LED C Gas lights yellow The refrigerator is in function Use rotary switch B to regulate the temperature in the main refrigerator compartment AUTO operation RM7XX5 L models are equi...

Страница 9: ...for 15 mins During this time the appliance is in stand by operation mode and only the AUTO LED lights up The use of naked flames is prohibited in petrol station environments If the refuelling stop las...

Страница 10: ...ting 12VDC 3 5W around the freezer compartment During summer months with high temperatures and humidity the metal frame may have water droplets forming To evapo rate these droplets switch on the frame...

Страница 11: ...the back of the refrigerator From there the water evaporates Positioning the storage rack 5 5 5 6 1 Fill the ice cube tray with drinking water 2 Place the ice cube tray in the freezer compartment 5 4...

Страница 12: ...1 Set energy selector switch A to position 0 OFF The appliance is now fully switched off 2 Secure the door open by means of the door stop The door will be slightly ajar This is to prevent mould from f...

Страница 13: ...es for replacement light bulbs 1 Upper door remove the two screws holding the control panel unsrcew upper hinge pin A and remove the door unscrew upper part of the door frame and the panel insert new...

Страница 14: ...A screw and keep it to hand 2 Take off the door by moving it upwards 3 Unscrew middle hinge and remove lower door 4 Remove the middle hinge 7 Affix the middle hinge 6 Positon the hinge at the opposit...

Страница 15: ...230V Possible cause Action you can take a On board fuse defective b No connection to supply voltage c AES gas operation despite connection to the supply voltage a Fit new fuse b Establish power connec...

Страница 16: ...nts Refrigerators manufactured by Dometic GmbH are free of CFC HCFC and HFC Ammonia a natural compound of hydrogen and nitrogen is used in the cooling unit as a coolant The non ozone hazardous cyclope...

Страница 17: ...05 L 1245x525x543 142 lit 25 lit 200 W 170 W ca 3 2 KWh 380 g 42 kg X standard door RM 7651 L 1245x525x570 150 lit 26 lit 200 W 170 W ca 3 2 KWh 380 g 43 kg X curved door RM 7655 L 1245x525x570 150 li...

Страница 18: ...l regulations EN 60335 1 EN 60335 2 24 EN 1648 1 EN 1648 2 The gas installation must comply with national regulations Technical regulations EN 1949 Technical regulations EN 732 Local and building cont...

Страница 19: ...e refrigerator off from the living area see FIG 1 4 Ensure that the refrigerator is installed level in the recess Finally push the refrigerator into the recess from the front This installation option...

Страница 20: ...walls of the ventilation shaft should be local to avoid the build up of condensation and drafts The parts of the shaft walls which are situated above and next to the exhaust for the combus tion gases...

Страница 21: ...tall the ventilation grilles cut two rectangles 451mm x 341mm in the outer wall of the vehicle for position of the cuts see point 6 3 L 500 To install the ventilation grilles cut a rectangle 451mm x 1...

Страница 22: ...there are four plastic sleeves with screws for securing the refrigerator The sidewalls or rails attached for securing the refrigerator must be designed in such a way that the screws will remain firmly...

Страница 23: ...iance The operating pressure corresponds to the standard pressure of the country of specification EN 1949 EN 732 Only one connection pressure is permissible for any one vehicle A plate showing the per...

Страница 24: ...P 30 mbar 30 37 50 28 37 30 37 50 30 Gas pressure Following proper installation a testing for leakage and a flame test must be car ried out by qualified personnel in compliance with EN 1949 A certifi...

Страница 25: ...supply through an on board fuse or automatic circuit breaker The power cable must be laid in such a way that it does not come in contact with hot components of the unit burner or with sharp edges If...

Страница 26: ...urrent flows via the D and S connection therefore no particularly large cross section is required for these connections approx 1mm Terminal strip DC connections RM 76x1 and RM 76x5 Retrofitting Connec...

Страница 27: ...lett violet braun brown weiss white gr n green gelb yellow rot red A B C D permanently connection DC Burner Control Device ignition unit Ground terminal block heating element DC Gas Valve temp sensor...

Страница 28: ...braun brown weiss white gr n green gelb yellow rot red A B C D permanently connection DC Burner Control Device ignition unit Ground terminal block heating element DC Gas Valve temp sensor heating ele...

Страница 29: ...29...

Страница 30: ...Dometic GmbH In der Steinwiese 16 D 57074 Siegen www dometic de caravan www dometic com...

Отзывы: