background image

22

INSTALLATION GUIDE

On installation of the appliance, the technical and administrative regulations of the 
country in which the vehicle will first be used must be adhered to. Otherwise the 
refrigerator must be installed as described in these instructions.
In Europe, for example, gas appliances, cable laying, installation of gas 
cylinders, as well as approval and checking for leaks must comply with 
EN 1949 for liquid gas units in vehicles.

Installation

The appliance and its fume extraction shall be installed in such a way as to be acces-
sible for servicing at all times and must be capable of easy removal and installation.
The appliance may only be installed by authorised personnel.
Installation and connection of the appliance must comply with the latest 
technical regulations, as follows:

The electrical installation must comply with national regulations.

Technical regulations EN 60335-1, EN 60335-2-24, EN 1648-1 , EN 1648-2

The gas installation must comply with national regulations.

Technical regulations EN 1949

Technical regulations EN 732

Local and building control department requirements

The appliance shall be installed in such a way that it is shielded from 
excessive heat radiation.

Excessive heat impairs performance and raises the energy consumption of the 
refrigerator.

Side installation

If the appliance is installed on the same side of the vehicle as the entrance 
door, it is desirable that the door does not cover the refrigerator’s vents. If this cannot
be avoided there must be a gap of at least 25mm between the door and the vents. 
(Fig.1, distance between door and wall min. 25 mm) 
Awnings are often placed at the door side of a caravan. In this case the ventilation 
grilles must be kept open and the awning area must be well ventilated. 
Otherwise the cooling performance could be impaired in high ambient temperatures.

8

8..0

0

8.1

Fig.1

Air vent grille not
blocked: OK!

8.1.1

Air vent grille blocked
Gap between door and vent
grille -  min. 25mm.

Any installation that is not carried out by qualified persons will jeo-
pardize the manufacturer's guarantee.

Содержание RMT 7650

Страница 1: ...CREATION VEHICLES RMT 7650 RMT 7850 RMT 7651 RMT 7851 RMT 7655 RMT 7855 Type C40 110 Model number Product number Serial number Please state for future reference EN OPERATING INSTRUCTIONS INSTALLATION...

Страница 2: ...perish quickly include all the products with a stipulated use by date and a minimum storage temperature of 4 C or less especially for meat poultry fish sausage pre packed foods Instructions Pack raw...

Страница 3: ...cor panel 15 5 12 Changing the doorhang 16 5 13 Troubleshooting 17 6 0 INSTRUCTION FOR OVEN 18 6 1 Operation of oven 18 6 2 Cleaning 18 6 3 Switching on the oven 19 6 4 Winter operation 19 7 0 GENERAL...

Страница 4: ...the refrigerator This will prevent accidental locking in or suffocation If you smell gas close the locking tap of the gas supply and the valve on the cylinder open the windows and leave the room do no...

Страница 5: ...d by the warranty The warranty does not cover any modifica tions to the appliance or the use of non original Dometic parts the warranty does not apply if the installation and operating instructions ar...

Страница 6: ...frame heating C manual ignition button Piezo ignition battery igniter G Galvanometer Refrigerator Refrigerator J switch on thermostat Oven A switch on and energy selection Refrigerator B gas electric...

Страница 7: ...tion When the appliance is first put into operation there may be a mild odour which will disappear after a few hours Ensure the living area is well ventilated The refrigerator will take several hours...

Страница 8: ...V lights green Appliance is in function 1 Set energy selector switch A to 12V The refrigerator operates without thermostatic control continuous operation 2 Use rotary switch B to regulate the temperat...

Страница 9: ...ration of the refrigerator and any other gas appliances e g cookers air is removed from the gas pipes The gas will then ignite without delay A 3 Set energy selector switch A to gas 4 Set rotary switch...

Страница 10: ...solar system This can be detected from the D connection of the alternator to the electronics or from the respective signal on the solar charge regulator Gas operation Gas operation is selected in the...

Страница 11: ...please call an authorised Dometic Service Centre Frame heating Additional functions RMT 7655 RMT 7855 5 2 4 C A Gas faults MES and AES Temperature setting display D with 4 LED to indicate the selecte...

Страница 12: ...exposed to sunlight and that this can reduce the efficiency of the refrigerator The air inside the refrigerator unit MUST be able to circulate freely without any hindrance see also Section 8 3 Ventil...

Страница 13: ...a cloth 5 Use a cloth to mop up the water from the freezer compartment 6 Switch the refrigerator back on again The layer of ice must never be removed forcibly nor may defrosting be accelerated using a...

Страница 14: ...nside the appliance A Switching off gas operation If the refrigerator is to be taken out of service for an extended period of time the on board shut off valve and the cylinder valve must be closed clo...

Страница 15: ...n A and remove the door unscrew upper part of the door frame and the panel insert new panel and fasten upper part of the door frame Please note Carry out following steps BEFORE mounting the upper door...

Страница 16: ...eep it to hand 2 Take off the door by moving it upwards 3 Unscrew middle hinge and remove lower door 4 Remove the middle hinge 7 Affix the middle hinge 6 Position the hinge at the opposite side of the...

Страница 17: ...d c Engine not running a Fit new fuse b Check battery charge it c Start engine Failure The refrigerator does not cool sufficiently Possible cause Action you can take a Inadequate ventilation to the un...

Страница 18: ...uld be repeated at regular intervals For cleaning there should only be used household cleaning solutions of the milder variety Use a soft cloth and lukewarm water Then rinse the appliance with clean w...

Страница 19: ...operation Check that the roof mounted flue outlet has not been blocked by snow leaves or similar 3 In order to adjust the oven to the required temperature release the knob from the depressed position...

Страница 20: ...ezer in 24 hrs compartment Refrigerator Refrigerator Refrigerator 7 2 7 7 0 0 RMT 7650 L 1515x525x596 150 lit 26 lit 190W 170 W ca 3 2 KWh 380 g 59 0 kg RMT 7850 L 1515x525x651 175 lit 31 lit 190W 170...

Страница 21: ...hints Refrigerators manufactured by Dometic GmbH are free of CFC HCFC and HFC Ammonia a natural compound of hydrogen and nitrogen is used in the cooling unit as a coolant The non ozone hazardous cyclo...

Страница 22: ...s installation must comply with national regulations Technical regulations EN 1949 Technical regulations EN 732 Local and building control department requirements The appliance shall be installed in s...

Страница 23: ...d in a draftproof manner EN 1949 This means that the combustion air for the burner is not taken from the living area and that exhaust fumes are prevented from entering the living area In no case use s...

Страница 24: ...is installation option facilitates the removal and installation of the appliance for servicing If the cavity between the caravan wall and the refrigerator is sealed so that fumes cannot penetrate the...

Страница 25: ...nto the recess floor intended for the unit s installa tion in order to avoid the accumulation on this floor of any non combusted gas which might escape according to EN 1949 The ventilation grilles mus...

Страница 26: ...ets screwed in the roof cut out Truma roof flue outlet AK3 L 500 L 500 Truma roof flue outlet AK3 Truma roof flue outlet AK3 Truma Art Nummer 30700 03 Truma pipe Truma Art Nummer 39450 00 The flexible...

Страница 27: ...for secu ring the refrigerator The sidewalls or rails attached for securing the refrigerator must be designed in such a way that the screws will remain firmly in place even when under increased load...

Страница 28: ...essure of the country of specification EN 1949 EN 732 Only one connection pressure is permissible for any one vehicle A plate showing the permanent clearly legible notice must be displayed in full vie...

Страница 29: ...l Qualified personnel are accredited experts who are able by virtue of their training and knowledge to vouch for the correct implementation of the leakage test A AT TT TE EN NT TI IO ON N 20 Nm max 15...

Страница 30: ...er or with sharp edges If the connection cable is damaged it must be replaced by the Customer Service at Dometic or by respectively qualified personnel in order to prevent any hazards Battery connecti...

Страница 31: ...e no particularly high current flows via the D and S connection therefore no particularly large cross section is required for these connections approx 1mm Terminal strip DC connections MES and AES Ret...

Страница 32: ...erior light A B D C terminal block heating element DC thermo couple battery igniter heating element DC heating element AC switch frame heating Ground Ground Ground mains connection Reed contacts senso...

Страница 33: ...alve temp sensor heating element DC heating element AC Switch Frame Heating ionisation electrode ignition plug gas burner Ground mains connection Reed contacts sensor switching lighting DC Power Modul...

Страница 34: ...alve temp sensor heating element DC heating element AC Switch Frame Heating ionisation electrode ignition plug gas burner Ground mains connection Reed contacts sensor switching lighting DC Power Modul...

Страница 35: ...35...

Страница 36: ...Dometic GmbH In der Steinwiese 16 D 57074 Siegen www dometic de caravan www dometic com...