EN
RMLT9xxx
Installing the refrigerator-oven combination
19
•
The outer wall must be fitted with an air inlet vent (fig.
3
1, page 4) and an outlet
vent (fig.
3
2, page 4) with ventilation grilles so that the heat generated can be
easily released to the outside:
–
Air inlet vent: Fit the ventilation grille as flush as possible to the floor of the
installation niche with a minimum cross-section of 400 cm².
–
Outlet vent: fit as far above the refrigerator as possible.
–
The distance between the air inlet and outlet vents must be at least 1050 mm
(fig.
5
, page 5).
•
Fit a heat conduction plate (fig.
3
3, page 4) above the refrigerator so that the
heat does not accumulate in the vehicle.
•
If the ventilation grille of the air inlet vent cannot be installed flush to the ground,
an additional inlet vent (fig.
3
6, page 4) must be provided in the floor for
releasing leaked gas.
•
The distance between the top of the oven and the ceiling must be at least
170 mm (fig.
3
, page 4).
•
If a roof flue (fig.
3
4, page 4) is being used: Fit a detachable panel (fig.
3
5,
page 4) above the oven so that you can always reach the flue pipe.
•
If you do not have a roof flue: Fit a panel with a ventilation grille (fig.
4
7, page 4)
above the oven.
•
The distance between the top of the oven and the flue outlet of the roof flue must
be between 250 mm and 1500 mm (fig.
5
, page 5).
•
Too large a gap between the refrigerator-oven combination and rear wall leads
to poor performance and increases the power consumption of the refrigerator.
Reduce the space behind the refrigerator-oven combination to create adequate
air inlet and outlet ventilation (fig.
6
, page 5).
•
The refrigerator-oven combination must not be installed at the side of the air inlet
and outlet vents as this leads to poor performance and increases the power
consumption of the refrigerator.
•
The air inlet and outlet vents must not be covered by vehicle parts (such as an
open door or by installing accessories such as bicycle racks) while operating.
•
Install the refrigerator-oven combination so that it is protected from excessive
heat, as this leads to poor performance and increases the power consumption of
the refrigerator.
•
The electrical installation must comply with national and local regulations.
European standards: EN 60335-1, EN 60335-2-24, EN 1648-1 and EN 1648-2.
•
The gas installation must comply with national and local regulations.
European standard: EN 1949.
RMLT9xxx-I-West.book Seite 19 Donnerstag, 7. Dezember 2017 12:22 12
Содержание RMLT 933 Series
Страница 2: ......
Страница 4: ...RMLT9xxx 4 6 2 3 4 5 1 10 mm 170 mm min 15 mm max 25 mm 3 7 6 2 3 1 min 15 mm max 25 mm 170 mm 4...
Страница 5: ...RMLT9xxx 5 1050 250 1050 250 5 15 25 mm 25 mm 25 mm 6...
Страница 6: ...RMLT9xxx 6 8 1 7 2 3 1 5 3 4 1 2 170 mm 1300 mm 65 55 1 0 3 5 9 1 0...
Страница 7: ...RMLT9xxx 7 1 2 3 4 1 3 2 4 LS230 LS330 a LS230 LS330 b LS230 LS330 c LS230 LS330 1 2 3 d...
Страница 8: ...RMLT9xxx 8 1 2 3 4 e 1 2 f 1 2 3 RMLT9430 g 1 2 3 RMLT9431 RMLT9435 h i 1 2 j...
Страница 9: ...RMLT9xxx 9 2x l 2x k n m o...
Страница 13: ...RMLT9xxx 13 RMLT93 RMLT94 u...