23
Refrigerator operation
4.14 Troubleshooting
Before notifying the authorised Service Center,
please check whether:
n
the instructions in section "Operating the
refrigerator" have been observed.
n
the refrigerator stands level.
n
it is possible to operate the refrigerator with
any available power source.
Possible cause
Action you can take
Failure: The refrigerator does not cool sufficiently.
n
Inadequate ventilation to the unit.
n
Thermostat setting is too low.
n
The condenser is heavily frosted.
n
Too much warm food has been stored inside within
short period of time.
n
The appliance has been running for only a short period
of time.
n
Ambient temperatures too high.
n
Check that the ventilation grilles are not covered.
n
Set thermostat to a higher level.
n
Check that the refrigerator door closes properly.
n
Allow warm food to cool down before storage.
n
Check whether the cooling compartment works after
approx. 4 - 5 hours.
n
Regularly remove ventilation grilles.
Possible cause
Action you can take
Failure: The refrigerator does not cool in gas operation mode.
n
Gas cylinder empty.
n
Is the upstream shut-off device open ?
n
Air in the gas pipe ?
n
Change gas cylinder.
n
Open shut-off device.
n
Switch off the appliance and start again. Repeat this
procedure 3 - 4 times, if necessary.
Possible cause
Action you can take
Failure: The refrigerator does not cool in 12V operation.
n
On-board fuse defective.
n
On-board battery discharged.
n
Engine not running.
n
Heating element defective (please also refer to failure
indication).
n
Fit new fuse.
n
Check battery, charge it.
n
Start engine.
n
Please inform the Dometic Customer Services.
Possible cause
Action you can take
Failure: The refrigerator does not cool in 230V operation.
n
On-board fuse defective.
n
Vehicle not connected to mains supply voltage.
n
AES
: Gas operation despite connection to the mains
supply voltage?
n
Heating element defective (please also refer to failure
indication).
n
Fit new fuse.
n
Make a connection to a mains power supply.
n
Appliance switches to gas operation due to insufficient
mains supply voltage (automatically switches back to
230V operation).
n
Please inform the Dometic Customer Services.
Содержание RML 8330