background image

29

Wiring diagram

Wiring diagram for RM 7XX1 L - models and RM 7XX5 L - models

6.9.6

Connections:

A = Ground heating element DC

B = Plus heating element DC 

C = Ground electronics

D = Plus electronics

Connections:

A = Ground heating element DC

B = Plus heating element DC 

C = Ground electronics

D = Plus electronics

Colours:

schwarz = black

violett = violet

braun = brown

weiss = white

grün = green

gelb = yellow 

rot = red

C

B

A

D

For the RM 7XX1 L models, there is no

X106 connection  (Solar S+  and  D+)!

Reed contacts

(sensor switching)

Ground

Ground

gas burner

heating element DC

ignition unit

valve

permanently

connection DC

lighting DC

heating element AC

mains

connection

temp. sensor

ignition

plug

ionisation

plug

Содержание RM7271L

Страница 1: ...6100 01 T B 06 2003 MANUAL ABSORPTION REFRIGERATOR for CARAVAN and MOTORHOME EN English OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS RM 7271 L RM 7275 L RM 7291 L RM 7295 L RM 7361 L RM 7365 L RM...

Страница 2: ...ct to change without notice Printed in Germany Dansk Deutsch English Espa ol Fran ais Italiano Nederlands Norsk Portugu s Suomi Svensk via INTERNET www dometic com Kundeservice Kundendienst Customer S...

Страница 3: ...rior light 13 5 11 Changing the decor panel 13 5 12 Changing the doorhang 14 5 13 Troubleshooting 15 5 14 Maintenance 16 5 15 Product liability 16 5 16 Environmental hints 16 5 17 Disposal 16 5 18 Ene...

Страница 4: ...e cylinder open the windows and leave the room do not switch on anything electrical extinguish naked flames Never open the cooling unit it is under high pressure Work on the gas flue system and electr...

Страница 5: ...his information on the data plate inside the refrigerator Damage in transit After removing the packaging check whether the refrigerator has been damaged during transportation Any damage sustained in t...

Страница 6: ...s propane butane The desired power option is selected by means of energy selector switch A Energy selector switch A has four settings AC mains power DC 12V Gas liquid gas OFF Appliances with automatic...

Страница 7: ...perature in the main refrige rator compartment A 1 Set energy selector switch A to 12V 2 Operating display C 12V lights green Appliance is in function 3 Use rotary switch B to regulate the temperature...

Страница 8: ...hts yellow The refrigerator is in function Use rotary switch B to regulate the temperature in the main refrigerator compartment Gas faults In the event of a gas fault e g gas cylinder empty the operat...

Страница 9: ...ected from the D connection of the alternator to the electronics or from the respective sig nal on the solar charge regulator Gas operation Gas operation is selected in the following circumstances No...

Страница 10: ...an authorised Dometic Service Centre Additional functions RM 7XX5 L models only Temperature setting cooling compartment As shown you are able to regulate the temperature of the cooling compartment if...

Страница 11: ...off the refrigerator as described in Section 5 8 Switching off 2 Remove the ice cube tray and food 3 Leave the refrigerator door open 4 After defrosting freezer compartment and fins free of frost wip...

Страница 12: ...it 5 9 park position vent position close open 5 7 1 Set energy selector switch A to position 0 OFF The appliance is now fully switched off 2 Secure the door open by means of the door stop The door wil...

Страница 13: ...e cover 2 Detach defective light bulb 3 Fit new light bulb 4 Clip the cover back in place 90 1 2 Note For 12V DC 1 light bulb 12V 2W Please contact Dometic Service Centres for replacement light bulbs...

Страница 14: ...s not always possible to change the door when the refrigerator is installed 1 Open the door unscrew the hinge screw and keep it to hand 2 Take off the door by moving it upwards 5 Attach the door 8 Scr...

Страница 15: ...230V Possible cause Action you can take a On board fuse defective b No connection to supply voltage c AES gas operation despite connection to the supply voltage a Fit new fuse b Establish power connec...

Страница 16: ...hints Refrigerators manufactured by Dometic GmbH are CFC free Ammonia a natural compound of hydrogen and nitrogen is used in the cooling unit as a coolant The non ozone hazardous cyclopentan is used...

Страница 17: ...821x525x541 86 lit 10 5 lit 125 W 120 W ca 2 6 KWh 260 g 27 kg X X RM 7361 L 821x486x541 88 lit 9 5 lit 135 W 130 W ca 2 6 KWh 260 g 28 kg X RM 7365 L 821x486x541 88 lit 9 5 lit 135 W 130 W ca 2 6 KWh...

Страница 18: ...18 Declaration of conformity 5 20...

Страница 19: ...ows The electrical installation must comply with national regulations Technical regulationsEN 60335 1 EN 60335 2 24 EN 1648 1 EN 1648 2 The gas installation must comply with national regulations Techn...

Страница 20: ...option is to provide the refrigerator with a cowl A The cowl A should ideally be affixed to the caravan wall not to the refrigerator Insert sealing strips at the bottom and sides of the cover Finally...

Страница 21: ...ower ventilation grille should be flush with the floor of the vehicle allowing any gas leakages heavier than air to escape directly into the open air If such an arrangement is not possible a hole must...

Страница 22: ...tractor insert in position only for upper ventilation system L100 and screw into position 1 Seal the mounting frame making it waterproof Item 1 does not apply for installation framess with an integrat...

Страница 23: ...tor In the sidewalls of the refrigerator there are four plastic sleeves with screws for securing the refrigerator The sidewalls or rails attached for securing the refrigerator must be designed in such...

Страница 24: ...the cooling capacity and will jeopardize the manufactur er s guarantee 1 Connect T piece E to adaptor F or tail pipe K as required and affix with screw G Ensure that heat baffle H is lodged in the cor...

Страница 25: ...exclusively to use liquid gas propane butane under no circumstances should town gas or natural gas be used EN 27418 A fixed pre set pressure regulator complying with EN 12864 must be connected to the...

Страница 26: ...0 37 50 28 37 30 37 50 30 Gas pressure Following proper installation a testing for leakage and a flame test must be car ried out by qualified personnel in compliance with EN 1949 A certificate of test...

Страница 27: ...ugh an on board fuse or automatic circuit breaker The power cable must be laid in such a way that it does not come in contact with hot components of the unit burner or with sharp edges If the connecti...

Страница 28: ...s There are no particularly high current flows via the D and S connection therefore no particularly large cross section is required for these connections approx 1mm Terminal strip RM 7XX1 L and RM 7XX...

Страница 29: ...eating element DC C Ground electronics D Plus electronics Colours schwarz black violett violet braun brown weiss white gr n green gelb yellow rot red C B A D For the RM 7XX1 L models there is no X106...

Страница 30: ...Dometic GmbH In der Steinwiese 16 D 57074 Siegen www dometic de caravan www dometic com...