9. TESTING LP GAS SAFETY
SHUTOFF

The gas safety shutoff must be tested after the refrigerator
is connected to LP gas supply.

To test the gas safety shutoff, proceed as follows:
A. Start the refrigerator according to the instructions, with

120 volts AC disconnected. See "

Section C. Operation

Instructions."

B. Check that the gas flame is lit. In Auto mode, the Auto

mode indicator lamp (A) is on. See FIG. 10.

C. Close the manual shutoff valve at the back of the

refrigerator.  (See FIG. 6)

D. Wait for one minute. The check indicator lamp (B) should

now be lit and the gas flame extinguished.

E. Remove cover and open the manual gas valve. Apply a

noncorrosive commercial bubble solution to burner jet
(see FIG. 6).

F. No bubbles should appear at the opening of the burner jet.

The presence of bubbles indicates a defective gas safety
shutoff, and service is required.

G. If no bubbles were present at the burner jet, the gas

safety valve is working properly. Rinse jet thoroughly
with fresh water before proceeding. Be careful not to
damage burner jet. Replace cover and turn the main
switch (1) OFF and back ON. (See "

Section C. Operation

Instructions, Item 2. Control Panel"). Normal operation of
the burner should return. Allow the burner to operate for
a minimum of 5 minutes.

WARNING

DO NOT use a flame to check for leaks.

10. 120 VOLT AC ELECTRICAL

CONNECTION

The refrigerator is equipped with a three-prong (grounded)
plug for protection against shock hazards, and should be
plugged directly into a properly grounded three-prong recep-
tacle. DO NOT cut or remove the grounding prong from this
plug. The power cord should be routed to avoid direct contact
with the burner cover, flue cover or manual gas shutoff valve
knob. The free length of the cord is two feet and therefore
recommended that the receptacle be located to the left side
of the refrigerator (viewed from the rear) and approximately
six inches from the floor (see FIG. 7). This allows easy
access through the vent door.

Flexible C ord

12 V olt
Terminal B lock

Inlet F itting

Manual G as
Shutoff V alve

Burner Jet

Drip P an

Evaporation
Tray

Protection
Cover

Flue
Baffle

Heater

Power
Module
Cover

Rating
Plate

FIG. 6

FIG. 7

11. 12 VOLT DC CONNECTION

This refrigerator model requires a 12 volt DC power source
to operate the automatic energy system (even though it is
designed to operate on 120 volts AC and gas). The DC lead
connections are at terminals located at the rear of the
refrigerator. (See FIG. 6). One lead is marked positive (+)
and the other negative (–). Correct polarity must be observed
when connecting to the DC supply.

Содержание RM2612

Страница 1: ...l your gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause injury or property dam age Refer to this manual For assis tance or additional information consult a qualified installer service agency or the gas supplier AVIS Cet a...

Страница 2: ...ionsare however contingentontheinstal lation being made in accordance with the following instruc tions as applicable In the U S A the installation must conform with 1 National Fuel Gas Code ANSI Z223 1 latest edition 2 ManufacturedHomeConstructionandSafetyStandard Title 24 CFR Part 3280 3 Recreational Vehicles ANSI A119 2 latest edition The unit must be electrically grounded in accordance with the...

Страница 3: ...rator and the wall behind the refrigerator NOTE Clearance N isthedistancebetweenthebottom of the lower vent to the roof material For ventilation height refertoSectionA Installation Item5 Ventilation Heights See FIG 2 FIG 2 FIG 3 Refrigerator Overall Installation Recess Model Dimensions Dimensions Dimensions Height Width Depth Height Width Depth Height Width Depth A B C h w d H W D RM2612 Inches 51...

Страница 4: ...ce in securing refrigerator in enclosure can cause leakage between the frame and cabi net The plastic caps are snapped in the front base to cover the screw heads and the decoration strip is secured to top frame SeeFIG 5 Anyspacebetweenthecounterstorage area or ceiling and top of the refrigerator should be blocked Theheatproducedattherearoftherefrigeratorwillbecome trapped in this space making the ...

Страница 5: ... should return Allow the burner to operate for a minimum of 5 minutes WARNING DO NOT use a flame to check for leaks 10 120 VOLT AC ELECTRICAL CONNECTION The refrigerator is equipped with a three prong grounded plug for protection against shock hazards and should be pluggeddirectlyintoaproperlygroundedthree prongrecep tacle DO NOT cut or remove the grounding prong from this plug Thepowercordshouldb...

Страница 6: ...oved in Step A PANEL DIMENSIONS MAX THICKNESS 5 32 4 mm Refr Models HEIGHT WIDTH TYPE MAX MIN MAX MIN RM2612 upper mm 306 304 515 513 inch 12 3 64 11 31 32 20 9 32 20 13 64 lower mm 819 817 515 513 inch 32 1 4 32 5 32 20 9 32 20 13 64 RM2812 upper mm 378 376 563 561 inch 14 7 8 14 51 64 22 11 64 22 3 32 lower mm 897 895 563 561 inch 35 5 16 35 15 64 22 11 16 22 3 32 FIG 8 1 1 1 1 2 3 4 5 6 13 CHAN...

Страница 7: ...tubingintheevaporatorsectionisspecificallyslopedto provide a continuous movement of liquid ammonia down ward by gravity through this section If the refrigerator is operated when it is not level and the vehicle is not moving liquidammoniawillaccumulateinsectionsoftheevaporator tubing Thiswillslowthecirculationofhydrogenandammo nia gas or in severe cases completely block it resulting in a loss of co...

Страница 8: ...attempt with the CHECK lamp illuminated or to clear turn off the CHECK lamp pressthemainpowerON OFFbuttontotheOFFand then ON position The control system will attempt a new 45 second ignition sequence 4 Ontheinitialrefrigeratorstart upongas 120voltsAC is not available it may take longer than 45 seconds to allow air to be purged from the gas line If the refrigeratorhasnotbeenusedforalongtimeortheLP ...

Страница 9: ...rigerator B FROZENFOODSTORAGECOMPARTMENT Quickfrozensoftfruitsandicecreamshouldbeplacedinthe coldestpartofthecompartmentwhichisonorjustbelowthe freezer shelf Frozen vegetables may be stored in any part of the compartment Thiscompartmentisnotdesignedfordeeporquickfreezing offood Meatorfish whetherraworprepared canbestored in the frozen food storage compartment provided they are precooled first in t...

Страница 10: ...e When parkedclosetoagasolinepump itispossiblethat the gasoline fumes could enter this type of appli anceandignitefromtheburnerflame CAUSINGA FIRE OR AN EXPLOSION FORYOURSAFETY whenrefueling shutoffallLP gas appliances which are vented to the outside 1 REFRIGERATOR REMOVAL Beforeworkingontherefrigerator makesuretheACvoltage and DC voltage leads are disconnected Shut off the gas supply Disconnect t...

Страница 11: ...allow it to air dry Reinstall and tighten burner jet FIG 12 MANUAL SHUT OFF VALVE Shown in open position Use a quarter dollar or a slotted screwdriver to change p osition SOLENOID VALVE BURNER MOUNTING SCREWS THERMOCOUPLE BURNER TUBE SPARK ELECTRODE BURNER JET PRESSURE TEST PORT INLET FITTING FIG 11 GAS EQUIPMENT ASSEMBLY DO NOT use a wire or pin when cleaning the burner jet asdamagecanoccurtothep...

Страница 12: ... fuse in to the fuse holder 5 Replace the power module cover Control System 3 amp ACHeater 5 amp 3 TROUBLESHOOTING Refrigerator Does Not Cool Properly A Burner jet clogged Clean See Section D Maintenance Service Item 1 Periodic Maintenance Paragraph E Item 19 B Check level of refrigerator C Ventingproblem Restriction in air flow across cooling unit D Heavy frost buildup on evaporator fins Defrost ...