background image

19

Draught-free installation

The refrigerator must be sealed in accordance with EN 1949.

Illustrated below is a typical approved method of sealing.

Proposal :

Using the Installation Sealing Kit from Dometic 
(available from Dometic)

Insert lipped seals (A) into the installation recesses at
the bottom and at each side (FIG 1, 2, 3).

Insert deflector plate (B), fitted with a lipped seal (A) of
heavy-duty, non- flammable material, into the
installation recess (see Fig. 4).

Insert deflector plate (B) in such a way that the hot air
escapes through the air vent grille into the open air.
Affix the discharge plate to the caravan wall, not to
the refrigerator !

In addition, discharge plate (B) with its lipped seal (A)
must seal the refrigerator off from the living area (see
FIG. 1,4).

Ensure that the refrigerator is installed level in the
recess.

Finally, push the refrigerator into the recess from the front.

This installation option facilitates the removal and installation of the appliance
for servicing.

Comment:

Other methods of sealing may be approved. However the chosen method must pre-
vent draughts entering the living space of the motorhome. Failure to seal correctly will 
allow warm air to collect around the refrigerator and its  performance will be affected.
If the cavity between the vehicle’s wall and the refrigerator is sealed so that fumes 
cannot penetrate the living area it is possible to vent the flue gas directly through the 
upper grille 
Do not use any kind of aluminium flue pipe (e.g. T-piece) to lead the flue gas out.

6.2

FIG. 1

FIG. 2

FIG. 3

FIG. 4

A

A

A

B

B

Deviations shall require the consent of the manufacturer.

Do NOT use any easily inflammable materials (in particular silicone sealing
agent or similar) for sealing! The device manufacturer's product liability
and guarantee shall lapse if such materials are used.

Содержание RM 7601 L

Страница 1: ...HOME RM 7601 L RM 7605 L RM 7651 L RM 7655 L RM 7801 L RM 7805 L RM 7851 L RM 7855 L Type C40 110 EN OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS A AB BS SO OR RP PT TI IO ON N R RE EF FR RI IG GE ER RA AT TO OR R Model number Product number Serial number Please state for future reference ...

Страница 2: ... that perish quickly include all the products with a stipulated use by date and a minimum storage temperature of 4 C or less especially for meat poultry fish sausage pre packed foods Instructions Pack raw and cooked foods separately e g in containers aluminium foil etc Only remove the outside packaging of single packs if all the necessary data such as the use by date for example can also be read o...

Страница 3: ... Winter operation 12 5 10 Interior light 13 5 11 Changing the decor panel 13 5 12 Changing the door 14 5 13 Troubleshooting 15 5 14 Maintenance 16 5 15 Product liability 16 5 16 Environmental hints 16 5 17 Disposal 16 5 18 Energy saving tips 16 5 19 Technical data 17 5 20 Declaration of conformity 17 6 0 INSTALLATION GUIDE 18 6 1 Installation 18 6 2 Draught free installation 19 6 3 Ventilation and...

Страница 4: ...e cylinder open the windows and leave the room do not switch on anything electrical extinguish naked flames Never open the cooling unit it is under high pressure Work on the gas flue system and electrical components must only be carried out by qualified service personnel It is imperative that the operating pressure should correspond to the data given on the model plate of the appliance Compare the...

Страница 5: ... the refrigerator Damage in transit After removing the packaging check whether the refrigerator has been damaged during transportation Any damage sustained in transit must be reported to the transportation company concerned no later than seven days after delivery of the goods DESCRIPTION OF MODEL REFRIGERATOR GUIDE Cleaning Before switching the refrigerator on to use it we recommend that you clean...

Страница 6: ...ed by means of energy selector switch A Energy selector switch A has four settings AC mains power DC 12V Gas liquid gas OFF Appliances with automatic energy selection have the additional setting AUTO 5 2 5 2 1 A Manual energy selection MES RM 76x1 L RM 78x1 L B Automatic and manual energy selection AES RM 76x5 L RM 78x5 L A energy selection switch E switch for frame heating with display LED B gas ...

Страница 7: ...temperature in the main refrige rator compartment A 1 Set energy selector switch A to 12V Operating display C 12V lights green Appliance is in function 2 Use rotary switch B to regulate the temperature in the main refrige rator compartment A 1 Set energy selector switch A to 230V Operating display C 230V lights green Appliance is in function C C If the operating display fails to light up it lights...

Страница 8: ...e case Priority 1 Solar 12V DC 2 230V AC 3 12V DC 4 Liquid gas The selected energy is displayed by the corresponding LED i e 230V A 1 Set energy selector switch A to gas 2 Set rotary switch B to MAX postion C 5 2 3 5 2 4 B Automatic Energy Selection RM 76x5 L RM 78x5 L only 1 Set energy selection switch A to position AUTO The LED AUTO illuminates Manual operation is possible at any time The refrig...

Страница 9: ... off for 15 mins During this time the appliance is in stand by operation mode and only the AUTO LED lights up The use of naked flames is prohibited in petrol station environments If the refuelling stop lasts longer than 15 mins the refrigerator should be switched off at the main switch A or switched over to another energy type Gas faults MES and AES If gas faults occur the operating LED C flashes ...

Страница 10: ...quipped with a frame heating 12VDC 3 5W around the freezer compartment During summer months with high temperatures and humidity the metal frame may have water droplets forming To evapo rate these droplets switch on the frame heating with switch A The LED B indicates that the heating is on The frame heating will draw 12V DC power continuously Observe LED B when the engine is shut off while parking ...

Страница 11: ... the back of the refrigerator From there the water evaporates Positioning the storage rack 5 5 5 6 1 Fill the ice cube tray with drinking water 2 Place the ice cube tray in the freezer compartment 5 4 Dismantling Only use drinking water 1 Loosen the front and back securing brackets 2 Move the storage rack to the left and remove it To fit the storage rack the reverse order applies 1 2 Products that...

Страница 12: ...lector switch A to position 0 OFF The appliance is now fully switched off 2 Secure the door open by means of the door stop The door will be slightly ajar This is to prevent mould from forming inside the appliance Switching off gas operation If the refrigerator is to be taken out of service for an extended period of time the on board shut off valve and the cylinder valve must be closed You should a...

Страница 13: ...tic Service Centres for replacement light bulbs 1 Upper door remove the two screws holding the control panel unsrcew upper hinge pin A and remove the door unscrew upper part of the door frame and the panel insert new panel and fasten upper part of the door frame Please note Carry out following steps BEFORE moun ting the upper door 2 Lower door unscrew both screws of the middle hinge pin B Pull out...

Страница 14: ...e A screw and keep it to hand 2 Take off the door by moving it upwards 3 Unscrew middle hinge and remove lower door 4 Remove the middle hinge 7 Affix the middle hinge 6 Positon the hinge at the opposite side of the door and insert lower door 8 Insert freezer compartment door and fasten the upper hinge pin 9 Replace the control panel and the rotary knobs 5 Place hinge pin on the opposite side 5 A ...

Страница 15: ... 230V Possible cause Action you can take a On board fuse defective b No connection to supply voltage c AES gas operation despite connection to the supply voltage a Fit new fuse b Establish power connection c Appliance switches to gas operation due to insufficient supply voltage automatically switches back to 230 V operation Failure The refrigerator does not cool sufficiently Possible cause Action ...

Страница 16: ...ints Refrigerators manufactured by Dometic GmbH are free of CFC HCFC and HFC Ammonia a natural compound of hydrogen and nitrogen is used in the cooling unit as a coolant The non ozone hazardous cyclopentan is used as a propellant in the manufacture of the PU foam insulation Disposal In order to ensure that the recyclable packaging materials are re used these should be sent to the usual local colle...

Страница 17: ...7805 L 1245x525x599 167 lit 30 lit 190W 170 W ca 3 2 KWh 380 g 44 0 kg X standard door RM 7651 L 1245x525x570 150 lit 26 lit 190 W 170 W ca 3 2 KWh 380 g 43 kg X curved door RM 7655 L 1245x525x570 150 lit 26 lit 190 W 170 W ca 3 2 KWh 380 g 43 kg X curved door RM 7851 L 1245x525x626 175 lit 31 lit 190W 170 W ca 3 2 KWh 380 g 44 7 kg X curved door RM 7855 L 1245x525x626 175 lit 31 lit 190W 170 W ca...

Страница 18: ...al regulations EN 60335 1 EN 60335 2 24 EN 1648 1 EN 1648 2 The gas installation must comply with national regulations Technical regulations EN 1949 Technical regulations EN 732 Local and building control department requirements The appliance shall be installed in such a way that it is shielded from excessive heat radiation Excessive heat impairs performance and raises the energy consumption of th...

Страница 19: ...in the recess Finally push the refrigerator into the recess from the front This installation option facilitates the removal and installation of the appliance for servicing Comment Other methods of sealing may be approved However the chosen method must pre vent draughts entering the living space of the motorhome Failure to seal correctly will allow warm air to collect around the refrigerator and it...

Страница 20: ...ould be local to avoid the build up of condensation and drafts The parts of the shaft walls which are situated above and next to the exhaust for the combus tion gases must be made of highly inflammable material The upper ventilation gril le should be positioned as high as possible above condenser A observe mini mum ventilation heights The lower ventilation grille should be flush with the floor of ...

Страница 21: ...stall the ventilation grilles cut two rectangles 451mm x 341mm in the outer wall of the vehicle for position of the cuts see point 6 3 L 500 To install the ventilation grilles cut a rectangle 451mm x 156mm in the outer wall of the vehicle for position of the cuts see point 6 3 L 205 R 500 Measurements of roof exhaust R500 Length Width Height 595 mm 205 mm 150 mm Roof cut out 87mm X 507 mm 1 Seal t...

Страница 22: ...crews for securing the refrigerator The sidewalls or rails attached for securing the refrigerator must be designed in such a way that the screws will remain firmly in place even when under increased load while the vehicle is moving Always insert screws through the sleeves provided otherwise structural parts embedded in the foam such as cables etc may be damaged Once the refrigerator is in its fina...

Страница 23: ...liance The operating pressure corresponds to the standard pressure of the country of specification EN 1949 EN 732 Only one connection pressure is permissible for any one vehicle A plate showing the permanent clearly legible notice must be displayed in full view at the point where the gas cylinder is installed The gas connection to the appliance must be installed securely and at zero potential usin...

Страница 24: ...with EN 1949 A certificate of testing must be issued qualified personnel Qualified personnel are accredited experts who are able by virtue of their training and knowledge to vouch for the correct implementation of the leakage test The refrigerator must be equipped with a gas cock C in the supply line to allow the supply to be disconnected Such a cut out device must be readily accessible to the use...

Страница 25: ...ot come in contact with hot components of the unit burner or with sharp edges If the connection cable is damaged it must be replaced by the Customer Service at Dometic or by respectively qualified personnel in order to prevent any hazards Battery connection The machine s mains 12V connection cable is connected observing correct polarity to a terminal strip The cabling must be direct and by the sho...

Страница 26: ...articularly high current flows via the D and S connection therefore no particularly large cross section is required for these connections approx 1mm Terminal strip DC connections MES and AES Retrofitting Connections A Ground heating element DC B Plus heating element DC C Ground electronics D Plus electronics RM7605 D alternator signal S AES input control signal solar charge regulator RETROFITTING ...

Страница 27: ...permanently connection DC Burner Control Device ignition unit Ground terminal block heating element DC Gas Valve temp sensor heating element DC heating element AC Switch Frame Heating ionisation electrode ignition plug gas burner Ground mains connection Reed contacts sensor switching lighting DC Power Module For operation it is compulsory to provide the device with a permanent 12V DC connection at...

Страница 28: ...violet braun brown weiss white grün green gelb yellow rot red A B C D permanently connection DC Burner Control Device ignition unit Ground terminal block heating element DC Gas Valve temp sensor heating element DC heating element AC Switch Frame Heating ionisation electrode ignition plug gas burner Ground mains connection Reed contacts sensor switching lighting DC Power Module ...

Страница 29: ...29 ...

Страница 30: ...Dometic GmbH In der Steinwiese 16 D 57074 Siegen www dometic de caravan www dometic com ...

Отзывы: