The gas connection to the appliance is effected by means of a suitable
coupling tube fitting L8, DIN 2353-ST, complying with EN 1949 (e. g. Ermeto).
26
Following proper installation, a testing for leakage and a flame test must be
carried out by *qualified personnel in compliance with EN 1949 .
A certificate of testing must be issued.
* qualified personnel
Qualified personnel are accredited experts who are able, by virtue of their training and knowled-
ge, to vouch for the correct implementation of the leakage test.
The refrigerator must be equipped with a gas cock
(
C
) in the supply line to allow the supply to be disconnected.
Such a cut-out device must be readily accessible to the user.
C
SW 14
SW 17
CAUTION
20 Nm
max
10 Nm
max
WARNING
The gas connection may only be carried out by a qualified personnel.