![Dometic RH 023 LDA Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/dometic/rh-023-lda/rh-023-lda_operating-instructions-manual_2519453008.webp)
8
If after checking all the above points, the refrigerator
is still not working satisfactorily, contact your nearest
service engineer. State the problem, model, product-
and serial-number.
(Details of the model, product- and serialnumber are
to be found on the data label in the top left of the
inside compartment.)
This refrigerator
is equipped with overheating
protection. An authorised service technician can
check whether this has been triggered or not.
In the event of a fault developing, contact your
nearest Service Centre-see local telephone directory.
14. Putting into operation
Technical data:
14.1 Connecting to electrical mains
The appliance may only be operated from
nominal voltage mains as shown on the data
plate. The appliance mains plug may be connected to
a mains socket earthed in accordance with
regulations.
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
The manufacturer declines any liability should
these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance
rating plate.
Only for UK:
The appliance is supplied with a 3 amp plug fitted. In
the event of having to change the fuse in the plug
supplied, a 3 amp ASTA approved (BS 1362) fuse
must be used. Should the plug need to be replaced
for any reason, the wires in the mains lead are
coloured in accordance with the following code:
Green and Yellow:
Earth
Blue:
Neutral
Brown:
Live
The wire coloured green and yellow must be
connected to the terminal marked with the letter E or
by the earth symbol
or coloured green and yellow.
The wire coloured blue must be connected to the
terminal N or coloured black.
Model
Type
Gross volume
Mains operation
Input
Energy consumption
Climate class
Refrigerant
RH 023 LDA
MF20-60
23 litres
220-240V (AC)
75W
0,8 kWh/24h
N
245g NH3 +H
2
O
RH 023 LDAG
MF20-60
23 litres
220-240V (AC)
75W
1,1 kWh/24h
N
245g NH3 +H
2
O