background image

Switching on

• Switch on the unit by pressing the 

- button on the electronic unit.

• Shortly after switching on, the inside temperature of the unit is shown on the

display.

Temperature Setpoint

• The temperature set point is the set target temperature of the appliance. 

• The set temperature set point can be displayed by briefly pressing the “SET” button

on the electronic unit. After 5 seconds the display switches back to the normal

temperature display.

• The factory set temperature is +3°C. 

• Any change of the setpoint temperature or any other parameter would have an

important influence on the proper functioning of the appliance and therfore can

only be done by a service technician.

Door Switch

• The integrated door switch detects any opening of the door. 

• During door opening the internal fan will be switched off, to avoid warm outside air

being sucked into the refrigerator. 

• An excessive door opening time will trigger a door alarm. 

Alarms

• When an alarm situation occurs, attempts must be made to find the cause of the

alarm and rectify it as soon as possible. If unable to do so, the necessary measures

must be taken immediately so that the goods stored are not damaged.

Temperature Alarm

• If the inside temperature of the appliance goes above or below the set alarm

values, both an acoustic and an optical alarm is triggered by the electronics. 

• The optical alarm consists of : 

1.)  the alarm symbol  

being shown on the display and 

2.)  the inside temperature of the appliance and the alarm message “HA” in case of

warm alarm or “LA” in case of cold alarm displayed alternately. 

• The display switches back to the normal temperature display once the alarm

situation is over. 

• The acoustic alarm can be muted for 30 minutes by pressing any button on the

electronics. If the alarm situation has not been rectified by the end of this period,

the acoustic alarm is activated again. 

AUX

AUX

8

Содержание RCCA 920

Страница 1: ...820 9506 00 ed0513 RCCA 920 Operating instructions ...

Страница 2: ...2 ...

Страница 3: ...g the batteries 6 Battery Guard 7 Operation 7 Control Panel 7 Charging LED 7 Electronic Control Unit 7 Switching on 8 Temperature Setpoint 8 Door Switch 8 Alarms 8 Temperature Alarm 8 Door Alarm 9 Alarm in the Event of Sensor Failure 9 Temperature history 9 Fan 10 Door lock 10 Automatic Defrosting 10 Cleaning 10 Maintenance 11 Address for service 11 Technical Data 11 ...

Страница 4: ...ient Safety Before using the unit read these operating instructions carefully including all the information on safety operation and maintenance Keep these operating instructions ready readily accessible and with the appliance so that all users understand the functions and safety regulations To prevent the unit from tilting it must never be moved on a diagonal level of more than 20 Before connectin...

Страница 5: ...ransit If you are unsure contact your sales outlet and ask them The unit must only be transported in an upright position and with closed door Environmental Protection Make your contribution to saving the environment Bear in mind that orderly and proper disposal is required Packaging materials and devices are always recyclable and should be taken for recycling Before scrapping an old unit remove th...

Страница 6: ...rcuit The circuit breaker is located on the backside of the refrigerator IMPORTANT On delivery the circuit breaker is in OFF position Before connection to AC make sure that the circuit breaker is switched to ON position If the circuit breaker is switched on afterwards the batteries will not charge There is no need to switch the circuit breaker off at any time Leave it in ON position during normal ...

Страница 7: ...harging LED The LED indicates the status of the battery charging process Yellow LED charging in process Green LED charging completed The LED only lights up if AC is connected The LED is off during normal operation of the unit using battery power For optimal battery performance the unit should only be disconnected from AC and put into operation when the LED has changed to green Electronic Control U...

Страница 8: ...r being sucked into the refrigerator An excessive door opening time will trigger a door alarm Alarms When an alarm situation occurs attempts must be made to find the cause of the alarm and rectify it as soon as possible If unable to do so the necessary measures must be taken immediately so that the goods stored are not damaged Temperature Alarm If the inside temperature of the appliance goes above...

Страница 9: ...lure If the temperature sensor fails or is defective a sensor alarm is generated by the electronics The display shows the error message P1 As the control sensor is no longer working the appliance is regulated by a preprogrammed ON OFF mode Together with the error message on the display an acoustic alarm sounds This acoustic alarm can be muted by pressing any button on the electronics for 30 minute...

Страница 10: ...e the compressor is switched off until the temperature reaches a predefined value If this temperature is not achieved after a certain timeout the appliance is switched on again During a defrosting process the defrosting symbol is shown in the display The defrost water is evacuated through the drainage tube at the rear of the appliance Cleaning The equipment should be cleaned inside and outside bef...

Страница 11: ...tre with exclusive use of original spare parts When replacing the batteries it must be ensured that they are replaced by batteries of the same type AGM type deep cycle min 100 Ah Address for service Regular Service Coca Cola Amatil 40 Mount Street North Sydney NSW 2060 Phone 132653 Further Assistance Dometic Australia Phone 1800 21 21 21 Technical Data Designation RCCA 920 External Dimensions WxDx...

Отзывы: