34
18. Technical Data
Gas operation butane (propane)
Rated thermal loading:
112 W
(118 W)
Min. thermal loading:
89 W
(86 W)
Connected load, gas:
8,1g/h
(8,4 g/h)
Connection pressure:
28-30/37 mbar
Categorie:
I3+
Climat class:
'N'
Electric operation:
220V-240V (mains) 50 Hz:
85W
12V (car battery):
85W
Capacity:
41 Ltr.
Refrigerant:
159g. H
2
O + 86g NH
3
The refrigeration cycle has been checked for leaks.
The appliance does not contain any CFCs/HCFCs.
Sodium chromate is used for corrosion protection (less than 2 weight % of
the coolant).
Appliances bearing this symbol must be deposited at the
designated local reception point for the disposal of electrical and
electronic equipment.
It is not permitted that this product be disposed of by way of the
normal household refuse collection system.
Dometic refrigerators bear this symbol on the specifications
plate (data plate) to be found in the interior of the unit.
This appliance complies with the following EEC directives:
LVD-Directive 73/23/EEC with amendment 90/683/EEC;
EMC-Directive 89/336/EEC;
Gas-Directive 90/396/EEC.