There are no restrictions on electrical operation.
Site of operation must be protected from rain and other water sources.

3. Storage of gas cylinders

Liquid gas cylinders should never be stored in unventilated areas or below

ground (funnel-shaped holes). Avoid direct sunlight. The gas cylinder should

not be exposed to temperatures in excess of 50°C.

4. Installation

To  be  installed  horizontally  on  a  smooth,  firm  or  any  other  appropriate

surface. If necessary, adjust/align using a spirit level or a water-filled vessel.
There should be a distance of at least 10cm between the back of the unit

and any other object (wall).
Avoid placing unit in direct sunlight and next to other sources of heat.
For good air circulation the air vents on the top and under sides, as well as

at the back of the cooling unit must not be obstructed.
This will result in a good, energy-saving cooling system.

5. Cleaning

Prior to initial use and later after defrosting, or prior to a prolonged period

out of operation, clean the container and lid with luke-warm water and, if

necessary,  washing-up  liquid. 

Warning:  do  not  inadvertently  press  or

force the opened door past its stop-point (this could cause the hinges

to  break).  Never  use  scouring  or  corrosive  agents  to  clean  the  unit.

Wipe cleaned surfaces dry with a soft cloth.

6. A/C operation

Do not use any additional form of energy (batteries/gas).
Check that the supply voltage corresponds with the line-voltage data on the

type-plate (see back of unit).
(The following instructions refer in the main to coolers manufactured for the

United Kingdom).
The mains lead of your refrigerator is fitted with a non-rewirable moulded-on

13  amp  plug  containing  a  3  amp  fuse.  It  is  a  regular  earthed  plug  for

connection to a regular earthed socket.
Due to the difference in the plugs used, an adapter will be necessary for

other countries.

GB

Содержание RC1600

Страница 1: ...207 5013 04 Type JCB 1 Gebrauchsanweisung Mode d emploi Instruzioni per l uso Operating instructions Gebruiksaanwijzing Instrucciones de manejo DE AT CH LU BE CH IT CH GB NL ES IE LU 0402...

Страница 2: ...ate ventilation as a failure to do this will result in component failure and possible food loss refer to relevant instructions for unit installation under point 4 Before defrosting cleaning or mainten...

Страница 3: ...ed This will result in a good energy saving cooling system 5 Cleaning Prior to initial use and later after defrosting or prior to a prolonged period out of operation clean the container and lid with l...

Страница 4: ...correctly Connections should be firmly made after all conductor strands are entered into the terminal posts When preparing the cable ends take care not to damage the outer sheath or the insulation sur...

Страница 5: ...kwise to position 0 a slight resistance will be felt just before this position Pull out mains plug 7 D C operation Do not use any additional form of energy mains gas A safety fuse must be installed in...

Страница 6: ...to reduce the pressure in the gas cylinder to the operating pressure specified on the rating plate no other pressure may be used Needle valve operated gas control taps are NOT suitable for use with t...

Страница 7: ...e burner every time after connection turn on the gas at the bottle and check the gas connections for leaks by applying a soap and water solution over them and watching for bubbles which would indicate...

Страница 8: ...sition 13 Food and drink storage Foodstuffs and drinks should always be sealed when stored in the cooling unit Thus changes in taste and smell are avoided Food and drink should be so placed in the coo...

Страница 9: ...lace the gas filter remove the filter from the duct and replace it with a new one Any other maintenance and repair works especially those relating to the cooling aggregate and the gas burner system ma...

Страница 10: ...in accordance with our guarantee conditions 18 Technical Data Gas operation butane propane Rated thermal loading 112 W 118 W Min thermal loading 89 W 86 W Connected load gas 8 1g h 8 4 g h Connection...

Страница 11: ...51 Fig 1...

Страница 12: ...52 Fig 3 Fig 2...

Страница 13: ...53 Fig 5 Fig 4 joint guarnizione afdichting junta joints guarnizione afdichtingen junta...

Страница 14: ...54...

Страница 15: ...55...

Страница 16: ...Printed by Xerox Hungary Ltd Rev 2003 12 17...

Отзывы: