8
9. Putting into operation
You must, in all instances, operate the appliance from
a single energy source only. Connecting several
energy sources at the same time will cause failure of
the appliance.
Technical data:
9.1
Connecting to 240 Volt
electrical mains
Make sure no other energy source is connected (gas,
12V).
The appliance may only be operated from nominal
voltage mains as shown on the data plate. The
appliance mains plug may be connected to a mains
socket earthed in accordance with regulations.
Model
RC 1600 EGP
Type
JCB - 1
Gross volume
33 litre
Mains operation
240V (AC)
Input
75 W (0,31 Amps)
Energy consumption
1.35 kWh/24h
Battery operation
12V (DC)
Input
75 W (6,25 Amps)
Energy consumption
150Ah/24h
Gas pressure (p)
2.75kPa (11” water gauge)
Gas type
LP
Jet size
24 (0,30 x 015 mm)
Gas consumption
0,48 Mj/h
Gas inlet
1/4” Male RH with Female Cone
Climate class
N
Refrigerant
158g H
2
O + 86g NH
3
9.2 Connecting to 12 Volt vehicle
battery
Make sure no other energy source is connected
(gas, 240V).
12V appliances must be connected to a vehicle
cigarette lighter, which is protected with a 10A fuse.
Note:
it is NOT recommended to run this 12 Volt
appliance from a 12 Volt cigarette lighter outlet.
9.3 Connecting to LP gas cylinder
Make sure no other energy source is connected
(240V, 12V).
The unit must not be connected to town or natural
gas pipelines. It is only suitable for use with
propane gas.
The cooling box is equipped for a specific gas-
pressure, 2.75kPa (11” w. g.). The rating-plate
states the pressure that is correct. It is important
that a non-adjustable pressure-regulator is used to
reduce the pressure in the gas cylinder to the
operating pressure specified on the rating-plate.
No other pressure may be used.
Needle valve-operated gas control taps are NOT
suitable for use with this appliance and must not be
used as a substitute for a pressure regulator.
Содержание RC 1600 EGP
Страница 11: ...11...