EN
Use charging converter
PerfectCharge
20
10
Use charging converter
10.1
Switch charging converter on/off
The charging converter turns on automatically as soon as it receives a positive control
signal. The status LED glows blue.
The charging converter switches off automatically when the control signal is no
longer present.
I
10.2
Adjust charging converter
I
You can adjust the device using the DIP switch (fig.
1
7, page 3).
Set switchover voltage/constant voltage
You can use the DIP switches S1 and S2 to set the value of the end-of-charge voltage.
NOTE
If the control signal of the charging converter is switched via the ignition,
the starter battery can discharge if the engine is not started in a timely
manner.
NOTE
Take the values for the charging end voltage and maintenance charge
voltage of your battery from the battery manufacturer's specifications.
S1
S2
Switchover voltage/constant voltage
12 V
24 V
ON
ON
14.4 V 28.8 V
OFF
ON
14.1 V
28.2 V
ON
OFF
14.7 V 29.4 V
OFF
OFF
DCC1224-2424--IO-16s.book Seite 20 Donnerstag, 8. März 2018 3:06 15