EN
MSI
Connecting the inverter
19
!
➤
Install a residual current circuit breaker in the socket distribution circuit.
9.6
Setting the earthing bridge (fig.
5
8, page 12)
(MSI1812T only)
➤
Remove the earthing screw from the top hole.
➤
Screw the screw into the bottom hole.
9.7
Connecting the MCR-7 or MCR-9 remote control
(accessory)
A
➤
Connect the remote control (accessory) to the remote port (fig.
3
2, page 10).
No. in
fig.
9
,
page 18
Explanation
1
230 V
w
power source
2
Additional devices, e.g. battery charger, refrigerator
3
DC power source (battery)
4
Inverter
5
Set grounding bridge (At delivery: not set, shown by dotted line)
6
Circuit breaker (residual current circuit breaker)
7
Socket distribution circuit for appliances
WARNING! Danger of electrocution!
If you wish to connect more than one appliance to the inverter and install
a socket distribution circuit, you must arrange a circuit breaker (residual
current circuit breaker) and set a grounding bridge in the inverter.
NOTICE!
•
Only plug in the connection to the remote control in the remote port.
The device can be damaged by connecting it incorrectly.
•
Ensure that the remote control and inverter are supplied with the
same input voltage.
•
Follow the instruction manual of the remote control.
MSI912-1812T-IO-AU.book Seite 19 Freitag, 23. Dezember 2016 3:11 15