![Dometic MPS 50 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/dometic/mps-50/mps-50_installation-and-operating-manual_2518117011.webp)
EN
MPS50
Using the mains rectifier
11
7
Using the mains rectifier
!
A
!
To avoid drops in voltage and therefore performance, keep the cable route as short
as possible and only disconnect it when necessary.
The cables between mains rectifier and compressor must not exceed 1.5 m and must
have a cross section of at least 2.5 mm².
WARNING!
Do not reverse the polarity. If the poles are reversed device may over-
heat and be damaged.
NOTICE!
Replace defective fuses with new ones of the same rating (12 A slow-
blow).
WARNING!
Ensure that the battery’s positive supply line is secured with a fuse
(fig.
2
1, page 11) of the following value:
•
at 12 V
g
: 15 A
•
at 24 V
g
: 7.5 A
The fuse must be installed as close to the battery as possible.
1
12/24 V
2
MPS50-IO-AU.book Seite 11 Mittwoch, 14. Dezember 2016 8:41 08