Dometic IB36H401RI Скачать руководство пользователя страница 20

AU

a

Cleaning the roof air conditioner

IBIS4

20

A

Regularly remove leaves and other dirt from the ventilation grilles (

1

) of the roof 

air conditioner. Make sure you do not damage the grilles in the process.

Clean the housing of the roof air conditioner and the air outlet unit occasionally 
with a damp cloth.

Clean the remote control with a slightly damp cloth from time to time. We 
recommend using a cleaning cloth for glasses to clean the display.

NOTICE! Beware of damage

The air outlet unit display screen (

1

) is acrylic and can be damaged by 

some common household chemicals.
Only use a mild solution of warm soapy water to clean it.
Chemical cleaners, window cleaners, alcohol, certain tensides, organic 
solvents, softeners and similar can damage the display.

1

6

1

7

IBIS4--O.book  Seite 20  Montag, 5. November 2018  7:56 19

Содержание IB36H401RI

Страница 1: ...IB36H401RI IB36H401RIY Air conditioning roof unit Operating manual EN AIR CONDITIONERS IBIS4 ...

Страница 2: ......

Страница 3: ...Explanation of symbols 4 2 Safety instructions 4 2 1 General safety 5 2 2 Operating the device safely 6 3 Target group for this manual 6 4 Intended use 6 5 Technical description 7 5 1 Control panel 7 5 2 Remote control 9 5 3 Air conditioning modes 10 5 4 Additional functions 11 6 Before initial use 11 7 Operating the roof air conditioner 12 7 1 Basic notes on operation 12 7 2 Using the remote cont...

Страница 4: ...e in the following cases Damage to the product resulting from mechanical influences and incorrect connection voltage Alterations to the product without express permission from the manufacturer Use for purposes other than those described in the operating manual WARNING Safety instruction Failure to observe this instruction can cause death or serious injury CAUTION Safety instruction Failure to obse...

Страница 5: ... hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be performed by children without supervision Only use the device as intended Do not make any alterations or conversions to the device Installation maintenance and repairs of the roof air conditioner may only be carried out by qualified personnel who are familiar with the risks involved when handlin...

Страница 6: ...icultural or construction vehicles Operate the device only if you are certain that the housing and the cables are undamaged 3 Target group for this manual This operating manual is for the user of the roof air conditioner 4 Intended use The Harrier Lite roof air conditioner is designed for installation on the roof of a caravan or recreational vehicle to provide reverse cycle heating and cooling It ...

Страница 7: ... air conditioner I 5 1 Control panel The control panel 1 is at the air outlet unit of the roof air conditioner NOTE The roof air conditioner can lower the temperature within the vehicle to a certain level The temperature depends on the type of vehicle the ambient temperature and the cooling capacity of your roof air conditioner Below an outer temperature of 16 C the roof air conditioner doesn t co...

Страница 8: ...an level when fan is adjusted Enables disables automatic mode chapter Air conditioning modes on page 10 Enables disables cooling mode chapter Air conditioning modes on page 10 Enables disables heating mode chapter Air conditioning modes on page 10 Adjusts the fan speed between Low Med or High showing as 1 2 or 3 on the air outlet unit display for a short time when changed Enables disables ventilat...

Страница 9: ...conditioner by remote control The following control and display elements are available on the remote control fig 3 page 9 No Button Explanation 1 Display Displays the following Time Selected room temperature target value in C or F Actual room temperature Air conditioning mode Fan level Symbols for active additional functions Battery status TURBO C F 1 3 ...

Страница 10: ...speed to rapidly cool or heat the inside of the vehicle After it reaches set temperature or is pressed again the fan will return to the previous setting Activates the sleep function chapter Additional functions on page 11 Sets the timer and the clock Finishes timer and clock settings Switches between temperature units Celsius C and Fahrenheit F Air conditioning mode Display message Explanation Aut...

Страница 11: ...temperature and fan settings and the air conditioner heats the interior to this temperature The fan will only start after 2 min on Low speed and the after around 5 min will got to the set fan speed after the evaporator reaches temperature Dehumidification Dehumidification removes moisture from the air with out heating or cooling the inside The fan speed is Low Ventilation The fan operates to circu...

Страница 12: ...se the control panel to switch the roof air conditioner to and from stand by mode make the settings select additional functions You can use the remote control to switch the roof air conditioner to and from stand by mode make the settings select additional functions CAUTION Beware of injury Do not insert your fingers or objects into the air nozzles or the intake grille Operating mode Features Off T...

Страница 13: ...ing to the IR receiver on the control panel you can activate the remote control or switch it to stand by independently from the roof air conditioner Press the button 7 3 Hints for improved use The following hints will optimise the performance of your roof air conditioner Improvetheheatinsulationofyourvehiclebysealinggapsandhangingreflective blinds or curtains on your windows If the vehicle has bee...

Страница 14: ... conditioning mode Select the desired air conditioning mode using the MODE button see chapter Air conditioning modes on page 10 The roof air conditioner confirms the receipt of the values with a high note The roof air conditioner is switched to the selected air conditioning mode NOTE When roof air conditioner is switched on it begins to condition the air to the values that were set most recently T...

Страница 15: ...ontrol Use the or button to select the desired temperature The roof air conditioner confirms the receipt of the values with a high note The temperature is set on the roof air conditioner Heating Mode In the Automatic and Heating modes you can specify a temperature between 16 C and 30 C via the remote control Use the or button to select the desired temperature The roof air conditioner confirms the ...

Страница 16: ...time in order to program the timer The time is indicated on the display of the remote control in 24 hour format Perform the following steps to set the time I Press and hold the button for 2 s The time flashes on the display of the remote control Use the or button to set the current time Press the longer than 2 s to increase or decrease the time quicker Press the SET button to confirm the time NOTE...

Страница 17: ... control batteries Replace the batteries if you see the symbol on the display The battery compartment is on the back of the remote control Gently push down the lid of the battery compartment and slide it open in the direction of the arrow Insert the new batteries 2x type AAA in the remote control as indicated in the battery compartment Close the cover of the battery compartment B Protect the envir...

Страница 18: ...f air conditioner The switch on time is set on the roof air conditioner The roof air conditioner is switched on with the selected air conditioning mode at the specified time Switch the roof air conditioner to stand by Setting the switch off time Press the button twice The OFF symbol flashes on the display of the remote control Use the or button to set the time when the air conditioner will be swit...

Страница 19: ...oof air conditioner The roof air conditioner starts in the selected air conditioning mode at the specified time and runs until the second specified time Switch the roof air conditioner to stand by Cancelling timer settings If you have set the timer you can cancel these settings as follows Press the button four times The timer symbol disappears The setting has been cancelled 8 Cleaning the roof air...

Страница 20: ...asionally with a damp cloth Clean the remote control with a slightly damp cloth from time to time We recommend using a cleaning cloth for glasses to clean the display NOTICE Beware of damage The air outlet unit display screen 1 is acrylic and can be damaged by some common household chemicals Only use a mild solution of warm soapy water to clean it Chemical cleaners window cleaners alcohol certain ...

Страница 21: ...he relevant regulations Interval Inspection maintenance Regularly Check the condensation water drainage Check whether the condensation water drainage channels 1 at the sidesoftheroofairconditionerareclearandthecondensationwater is able to escape Regularly Clean the filter of the air discharge unit Insert a flat screwdriver or knife into the handle 1 to pull the filters 2 slightly out Remove the fi...

Страница 22: ...low or all air nozzles are closed Not cooling well The roof air conditioner is not set to cooling Set the roof air conditioner to cooling The ambient temperature is above 52 C The roof air conditioner is only designed for ambient tempera tures of up to 52 C The temperature set is higher than the room temperature Select a lower temperature The ambient temperature is below 16 C The roof air conditio...

Страница 23: ...efective Contactanauthorised service agent or Dometic Water enters the vehicle The condensation water drainage openings are clogged up Clean the drainage openings for condensation water The seals are damaged Contactanauthorised service agent or Dometic Roof air conditionerdoes not switch on No supply voltage 240 V AC connected Check the power supply The voltage is too low under 200 V AC Contactana...

Страница 24: ...terials and natural resources atmospheric emissions discharge of liquids waste management and recycling contamination of the soil In order to minimise environmental impact the manufacturer provides a series of indications here below that should be taken into account by all those who for what ever reason interact with the appliance during its working life All packing components must be disposed of ...

Страница 25: ...n operation or undergoing repairs and maintenance work make sure that the refrigerant circuit is not damaged and refrigerant cannot escape It acts as a greenhouse gas and should not be allowed into the environment M If you wish to finally dispose of the product ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulatio...

Страница 26: ...ng capacity based on ISO 5151 3017 W Rated input voltage 220 240 Vw 50 Hz Rated current in cooling mode 6 9 A Rated current in heating mode 6 5 A Required fuse 10 A Operating temperature range 2 C to 52 C Refrigerant R410A Refrigerant quantity 0 750 kg CO2 equivalent 1 566 t Global warming potential GWP 2088 Protection class IPX4 Suggested max vehicle length with insulated walls 7 m Dimensions L x...

Страница 27: ......

Страница 28: ... 9 622 1490 64 9 622 1573 Mail customerservices dometic co nz NORWAY Dometic Norway AS Østerøyveien 46 N 3232 Sandefjord 47 33428450 47 33428459 Mail firmapost dometic no POLAND Dometic Poland Sp z o o Ul Puławska 435A PL 02 801 Warszawa 48 22 414 3200 48 22 414 3201 Mail info dometic pl PORTUGAL Dometic Spain S L Branch Office em Portugal Rot de São Gonçalo nº 1 Esc 12 2775 399 Carcavelos 351 219...

Отзывы: