background image

[page 6]  |  gpelectric.com

Equipment Safety

WARNING!  

Lethal Voltage

Review the system configuration to identify all possible sources 

of energy.  Ensure ALL sources of power are disconnected before 

performing any installation or maintenance on this equipment.  

Confirm that the terminals are de-energized using a validated 

voltmeter (rated for a minimum 1000 VAC and 1000 VDC) to verify 

the de-energized condition.

Do not perform any servicing other than that specified in the installation 

instructions unless qualified to do so, or have been instructed to do so 

by Go Power! Technical Support personnel.

To avoid electric shock, disconnect the DC input and AC input of 

the inverter at least 5 minutes before performing any installation 

or maintenance.

Do not tighten the AC and DC terminals or pull on the AC and DC wiring 

when the inverter is running.

WARNING!  

Fire Hazard

Do not keep combustible or flammable materials in the same room with 

the equipment.  Some products contain relays with moving parts and 

are not ignition-protected.

Ensure AC, DC, and ground cable sizes conform to local codes.  See 

product manuals for minimum size requirements.  

Ensure all conductors are in good condition.  

Do not operate the unit with damaged or substandard cabling.

CAUTION!  

Equipment Damage

When connecting cables from the inverter to the battery terminals, 

ensure the proper polarity is observed.  Connecting the cables 

incorrectly can damage or destroy the equipment and void the 

product warranty.

Thoroughly inspect the equipment prior to energizing.  Verify that no 

tools or equipment have been inadvertently left behind.

Keep all vents clear of obstructions that can prevent proper air flow 

around, or through, the unit.

CAUTION!  

Equipment Damage

Static electricity may damage electronic components.  Take appropriate 

steps to prevent such damage to the inverter; otherwise the warranty 

may be annulled.

GENERAL INFORMATION

Содержание Go Power! GP-1750HD

Страница 1: ...nual GP 1750HD GP 3000HD GP 5000HD 2021 Go Power Worldwide Technical Support and Product Information gpelectric com Go Power Dometic 201 710 Redbrick Street Victoria BC V8T 5J3 Tel 1 866 247 6527 8069...

Страница 2: ...17 4 6 BATTERY PRECAUTIONS 19 4 7 DC WIRING SIZING 20 4 8 DC GROUNDING 21 5 OPERATION 22 5 1 OPERATING PRECAUTIONS 22 5 2 CONNECTING AC LOADS 23 5 3 CONTROLS AND INDICATORS 23 5 4 OPTIONAL ON OFF REM...

Страница 3: ...national electrical codes These instructions are for use by qualified personnel who meet all local and governmental code requirements for licensing and training for the installation of electrical powe...

Страница 4: ...any way See the Warranty section for instructions on returning the equipment WARNING Hazard to Human Life This type of notation indicates that the hazard could be harmful to human life WARNING Shock H...

Страница 5: ...omponents If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired People with pacemakers should consult their physician s before...

Страница 6: ...NING Fire Hazard Do not keep combustible or flammable materials in the same room with the equipment Some products contain relays with moving parts and are not ignition protected Ensure AC DC and groun...

Страница 7: ...smoke or allow a spark or flame near the batteries Always use insulated tools Avoid dropping tools onto batteries or other electrical parts Never charge a frozen battery Never use old or untested bat...

Страница 8: ...s If battery acid contacts skin or clothing wash immediately with soap and water If acid enters the eye immediately flood it with running cold water for at least 20 minutes and get medical attention a...

Страница 9: ...her representation warranty or guarantee that the information is accurate correct reliable or current The specifications in this manual are for reference purposes only and are subject to change withou...

Страница 10: ...2 FEEL FREE TO MOVE RESIZE THIS TABLE MATERIAL FINISH FINISH SPEC COLOR A B C 6 7 8 ALL COMPONENTS AND PROCESSES TO BE ROHS COMPLIANT CERTIFICATE REQUIRED WITH INITIAL SHIP NOTES 1 TYPE YOUR NOTES IN...

Страница 11: ...ED DATA COPYRIGHT 2012 BY Carmanah Technologies Corp Victoria BC Canada ALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE REPRODUCED STORED IN A RETRIEVAL SYSTEM OR TRANSMITTED IN ANY FORM WITHOUT T...

Страница 12: ...USB OUTPUT VOLTAGE 4 75 5 25 VDC 2 1 A OUTPUT WAVEFORM MODIFIED SINE WAVE AC OUTPUT CONNECTIONS 3 STANDARD NORTH AMERICAN OUTLETS USB CONNECTIONS 1 USB PORTS SIGNAL AND CONTROL REMOTE CONTROLLER PANE...

Страница 13: ...USB OUTPUT VOLTAGE 4 75 5 25 VDC 2 1 A OUTPUT WAVEFORM MODIFIED SINE WAVE AC OUTPUT CONNECTIONS 4 STANDARD NORTH AMERICAN OUTLETS USB CONNECTIONS 1 USB PORTS SIGNAL AND CONTROL REMOTE CONTROLLER PANE...

Страница 14: ...N USB OUTPUT VOLTAGE 4 75 5 25 VDC 2 1 A OUTPUT WAVEFORM MODIFIED SINE WAVE AC OUTPUT CONNECTIONS 4 STANDARD NORTH AMERICAN OUTLETS USB CONNECTIONS 1 USB PORTS SIGNAL AND CONTROL REMOTE CONTROLLER PAN...

Страница 15: ...wer supply with lower voltage will not oper ate the Inverter correctly and higher voltage could damage the Inverter 5 Connect input polarity properly Incorrect connection will damage the Inverter and...

Страница 16: ...internal temperature gets too high Note even though this Inverter has built in mechanisms to minimize damage these situations should be avoided because they can still damage the Inverter or battery 4...

Страница 17: ...member the terminal is positive and the terminal is negative Place the lug connector between the washers and tighten the terminal screw or nut to clamp the wires securely Ensure connections are tight...

Страница 18: ...of flammable fumes as explosion or fire may result 8 Set the power switch to the ON position Check the meters and indicators on the front panel of the Inverter The Function LEDs should be green showin...

Страница 19: ...minals together to the other cable The following points must be observed for the DC Wiring The DC positive and negative cables connected to the Inverter from the battery bank should be linked together...

Страница 20: ...o prevent frequent low input voltage warnings and shutdown Only use high quality copper wire The cables should be as short as possible and the overall length of both cables added together should be le...

Страница 21: ...referred to as the Earth ground or another designated ground For example on an RV the metal frame of the RV is designated as the negative DC ground RV ground The DC ground wire connection on the Inver...

Страница 22: ...ce becomes extremely hot turn the power remove the device and do not use with the Inverter 5 Check for breakage of parts and any other condition that may affect the Inverter s operation If damaged hav...

Страница 23: ...ge the battery to the point that it will no longer start the engine If needed operate the engine pe riodically to maintain the batteries charge Do not operate a vehicle s engine in an enclosed space 5...

Страница 24: ...r refuses to start observe the battery voltage indicator while trying to start the motor If the battery voltage indicator drops below 11V while the Inverter is attempting to start the motor this may b...

Страница 25: ...arged but the voltage still drops below 11 volts you may need to use a larger battery 5 6 INPUT VOLTAGE The Inverter will operate from input voltage ranging 10 5 16V If the voltage drops below 10 5 V...

Страница 26: ...replace battery 5 Clean and tighten connection 6 Remove charging source and make sure correct battery is being used and connected correctly OUTPUT VOLTAGE IS INCORRECT Input voltage is too high or to...

Страница 27: ...erson using only identical replace ments This will ensure that the safety of the Inverter is maintained 4 Fuses must be replaced with fuses of the same type and rating only 7 2 MAINTENANCE Very little...

Страница 28: ...leshoot the problem If trouble persists 1 Call your Go Power Technical Support team 1 866 247 6527 or 2 Return defective product to place of purchase Unless approved by Go Power Management all product...

Страница 29: ...e Knowing for sure if your appliances are being recycled properly is tricky If you re in doubt just ask Recyclers that are certified should gladly show you their certification If the re cycler is cert...

Страница 30: ...2021 Go Power Worldwide Technical Support and Product Information gpelectric com Go Power Dometic 201 710 Redbrick Street Victoria BC V8T 5J3 Tel 1 866 247 6527 80691_MANUAL_GP 1750 3000 5000 HD_RevC...

Отзывы: