![Dometic FreshWell 3000 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/dometic/freshwell-3000/freshwell-3000_instruction_2518272010.webp)
EN
Installation
FreshWell3000
8
•
Place the assembly template into the chosen compartment and check the space
available for the openings in the floor.
•
To minimize the transmission of noise and vibration during operation, the under-
bench air conditioner should have a all around minimum clearance of 30 mm to
walls and furniture.
•
The under-bench air conditioner must be installed on the floor.
•
Keep a distance of 200 mm between the front of the under-bench air conditioner
and the walls of the compartment to facilitate filter replacement.
•
Installing the under-bench air conditioner into an external compartment (e.g.
false bottoms), the air to be treated must be drawn in from the vehicle’s
passenger compartment.
•
Suctioning of outside air can significantly reduce the power of the system.
Note on electrical system (see fig.
c
)
•
Only a qualified electrician should connect the under-bench air conditioner to
the electrical power.
•
Check that the voltage specification on the type plate is the same as that of the
power supply.
•
Do not lay cables which are loose or bent next to electrically conductive material
(metal).
No. in fig.
c
Description
1
Motor ventilator (inner)
2
Motor ventilator (outer)
3
Capacitor
4
Compressor
5
Temperature sensor
6
PCB
7
PCB display
8
PCB interface
9
Soft start
10
Valve
11
Resistor
FreshWell3000-I-16s.book Seite 8 Mittwoch, 12. Dezember 2018 2:11 14