Troubleshooting
37
11
Troubleshooting
Problem
Cause
Remedy
Roof air
conditioner
constantly switches
itself off.
Icing sensor has tripped.
Outer temperature is too low or all air
nozzles are closed.
No cooling
capacity
The roof air conditioner is not set to
cooling.
➤
Set the roof air conditioner to
cooling.
The ambient temperature is above 52 °C. The roof air conditioner is only
designed for ambient temperatures of
up to 52 °C.
The temperature set is higher than the
room temperature.
➤
Select a lower temperature.
The ambient temperature is below 16 °C. The roof air conditioner is only
designed for ambient temperatures
above 16 °C.
One of the temperature sensors is
defective.
➤
Contact an authorised workshop.
The vaporiser fan is damaged.
The condenser fan is damaged.
Low air output
The air intake section is clogged up.
➤
Remove any leaves and other dirt
from the ventilation grilles of the
roof air conditioner.
The blower is defective.
➤
Contact an authorised workshop.
Water enters the
vehicle
The condensation water drainage open-
ings are clogged up.
➤
Clean the drainage openings for
condensation water.
The seals are damaged.
➤
Contact an authorised workshop.
FreshJet-ADB2015-O-AU.book Seite 37 Freitag, 26. Januar 2018 9:19 09
Содержание FJ 2200
Страница 1: ...FJ 2200 FJ 3200 Air conditioning roof unit Operating manual EN AIR CONDITIONERS FRESHJET ...
Страница 2: ......
Страница 9: ...EN FreshJet Technical description 9 6 1 Components 1 2 4 3 FreshJet 2200 FreshJet 3200 1 2 4 3 1 ...
Страница 11: ...EN FreshJet Technical description 11 FreshJet 2200 2 ...
Страница 12: ...EN Technical description FreshJet 12 FreshJet 3200 3 ...
Страница 13: ...EN FreshJet Technical description 13 4 ...
Страница 43: ......