15.1 Connecting to electrical mains

The  appliance  may  only  be  operated  from

nominal  voltage  mains  as  shown  on  the  data

plate. The appliance mains plug may be connected to

a  mains  socket  earthed  in  accordance  with

regulations.
Any  electrical  work  required  to  install  this  appliance

should  be  carried  out  by  a  qualified  electrician  or

competent person.

The  manufacturer  declines  any  liability  should

these safety measures not be observed.

Electrical Requirements

Before switching on, make sure the electricity supply

voltage is the same as that indicated on the appliance

rating plate.

16. Environmental protection 

information

The appliance does not contain any CFCs/HCFCs.
Ammonia (natural hydrogen and nitrogen compound)

is used as a refrigerating agent in the refrigeration unit.
The  ozone-friendly  cyclopentane  is  activated  as  a

motive agent for the PU foam insulation. 
Sodium  chromate  is  used  for  corrosion  protection

(less than 2 weight % of the coolant).

17. Recycling

After unpacking the appliance, the packing materials

should  be  delivered  to  a  local  collection  site.  At  the

end  of  its  useful  lifetime,  the  appliance  should  be

delivered to a specialized collection and reprocessing

firm, which reclaims the usable materials. The rest is

properly destroyed. 

This  appliance  complies  with  the  following  EEC

directives:

LVD-Directive 73/23/EEC  with  amendment 

90/683/EEC

EMC-Directive   89/336/EEC

Содержание EA 3080

Страница 1: ...207 5166 20 EA 3100 EA 3080 EA 3140 RA 80 RA 140 RH 200 miniCool J Operating Instructions ...

Страница 2: ...ent failure and possible content loss See installation instructions Parts which heat up should not be exposed Wherever possible the back of the product should be close to a wall but leaving the required distance for ventilation as stated in the installation instructions Before defrosting cleaning or maintenance work is carried out be sure to switch off the appliance and unplug it DO NOT USE SHARP ...

Страница 3: ...ulation 6 Ice cubes 7 Useful suggestions 8 Defrosting cleaning and maintenance 9 Changing the lightbulb 10 Reversing the door hang 11 Replacing the decorative door panel 12 Assembly of door handle 13 Changing the feet 14 Customer service 15 Putting into operation technical data 15 1 Connecting to electrical mains 16 Environmental protection information 17 Recycling ...

Страница 4: ...port it immediately to the transportation firm 2 View of the appliance 1 Door lock 2 Sensor 3 Thermostat knob 4 Evaporator 5 Lamp if available Figure 1 IN CASE IF YOUR REFRIGERATOR IS EQUIPPED WITH LOCK DOMETIC RT DO NOT ACCEPT LIABILITY FOR LOSS OR DAMAGE OF KEYS HOWEVER WE WOULD BE HAPPY TO SUPPLY A COMPLETE LOCK AND KEY REPLACEMENT EA 3100 EA 3080 EA 3140 ...

Страница 5: ...tion process the appliance gives off heat from the condenser under the upper part of the rear cover into the surrounding air The more ventilated the condenser is the more effective the refrigeration will be The other condition for satisfactory operation is that the appliance stands on a flat surface This is best seen by placing a glass of water on top of the appliance It is important that the appl...

Страница 6: ...socket outlet and switch on the socket The cooling fins should show signs of cooling after about 3 hours The refrigerator needs about 6 hours at normal ambient temperature to reach 6 C in the storage compartment 5 1 Temperature regulation The usual setting required is in the region of 2 to 3 on the thermostat knob Fig 4 but this can vary with conditions of load and installation If it is found nece...

Страница 7: ...nit for two hours in every 24 hours The frost will melt and the defrost water will run through the drain tube from the drip channel into an evaporating vessel located at the bottom rear of the refrigerator Fig 5 The defrost water will evaporate automatically into the circulating air and the vessel will not need emptying manually If we want to switch off the unit turn the thermostat knob to 0 disco...

Страница 8: ...ge 5 Slide the decorative panel 6 out of the door frame and insert the new panel 7 so that the upper edge of the panel runs exactly parallel to the upper edge of the frame A new panel can be inserted more easily into the upper edge of the frame when the two corners are cut off by approx 5 x 5mm 8 Put the frame edge 5 back in place and secure with screws Place the door on the lower hinge 9 slot the...

Страница 9: ...ator level Has the ventilation become obstructed If after checking all the above points the refrigerator is still not working satisfactorily contact your nearest service engineer State the problem model product and serial number Details of the model product and serialnumber are to be found on the data label in the top left of the inside compartment This refrigerator is equipped with overheating pr...

Страница 10: ...ironmental protection information The appliance does not contain any CFCs HCFCs Ammonia natural hydrogen and nitrogen compound is used as a refrigerating agent in the refrigeration unit The ozone friendly cyclopentane is activated as a motive agent for the PU foam insulation Sodium chromate is used for corrosion protection less than 2 weight of the coolant 17 Recycling After unpacking the applianc...

Страница 11: ...11 ...

Страница 12: ...Printed by Xerox Hungary Ltd Rev 2003 08 07 ...