Dometic DVS02 Скачать руководство пользователя страница 10

10

Operation 

Dometic Vacuum Status Control Panel

7 Operation

7.1 

Vacuum status monitor  

(fig . 

3

 , page 2)

1 .  When power switch is turned ON, the 

green

 light indicates that there is sufficient vacuum in the 

VacuFlush system to flush the toilet (A) .

2 .  When power switch is turned ON and the 

red

 light glows, this indicates that there is NOT sufficient 

vacuum in the system to flush the toilet (B) . 

Do not flush toilet, or blockage may occur in system.

Notes

 

If green and red light constantly cycle on and off between flushes, there is a possible 
vacuum leak in the system . (An idle VacuFlush system should not cycle more frequently 
than once every three hours .)

If green light is ON but there is no vacuum in system, a blockage has likely occurred 
between the toilet and vacuum tank . Open flush ball in toilet bowl and use standard toilet 
plunger to unblock .

After a period of time, if red light seems to remain lit longer than when toilet system was 
new, duckbill valves in vacuum pump may require replacement .

Caution! 

If DVS02 is connected to a “full tank” sensor and holding tank is empty, a continuous red 
light may indicate extensive vacuum loss due to blockage, pump failure or leak . 

Turn off 

vacuum system and repair as soon as possible.

7.2 

“Full tank” monitor  

(only when connected to “full tank” sensor in waste holding tank)

1 .  When power switch is turned ON, the red light glows, and the vacuum pump is not running, this 

indicates that the holding tank is full and needs to be pumped out . 

Do not flush toilet, or blockage 

may occur in system.

 

7.3 

Circuit breaker control  

(fig . 

3

 , page 2)

1 .  Turn the power switch to the ON position (A, B) for normal toilet operation .  One light will always be lit 

to indicate there is power to the VacuFlush toilet system .  Allow system vacuum to fully recharge and 
green light to illuminate before turning power OFF for any reason .

2 .  During the night or other extended periods when the toilet or vacuum system is not needed to  

operate, turn the power switch to the OFF position (C) .

Содержание DVS02

Страница 1: ...de surveillance de r servoir Mode d emploi 19 Sistema de control del dep sito Manual de instrucciones 26 Tankmonitorsysteem Gebruiksaanwijzing 33 Sistema di controllo del serbatoio Manuale di istruzio...

Страница 2: ...2 1 2 4 3 A B C D 1 2 3 A B C Dometic Vacuum Status Control Panel...

Страница 3: ...3 Dometic Vacuum Status Control Panel 4 A C H G F B D E...

Страница 4: ...4 Dometic Vacuum Status Control Panel...

Страница 5: ...ure for an effective flush and the power switch allows turning off electrical power to the vacuum system during periods when the toilet is not in use and you do not want the vacuum system to operate I...

Страница 6: ...ircuit breaker protects pump from damage Power indicator for toilet system Indicates when toilet system power is off or loss of electrical power 12 or 24 V DC operation 4 Components fig 1 page 2 Ref D...

Страница 7: ...ocation Route additional wire according to appropriate wiring diagram fig 5 7 pp 8 9 wiring diagram schematics depending on your application to panel location Make sure wires extend out through access...

Страница 8: ...8 6 2 DVS02 system wiring schematics Installation Dometic Vacuum Status Control Panel 5 DVS02 panel with vacuum generator...

Страница 9: ...9 Dometic Vacuum Status Control Panel Installation 7 6 DVS02 panel with vacuum holding tank VHT DVS02 panel with vacuum tank and vacuum pump...

Страница 10: ...in lit longer than when toilet system was new duckbill valves in vacuum pump may require replacement Caution If DVS02 is connected to a full tank sensor and holding tank is empty a continuous red ligh...

Страница 11: ...or obligation other than that set forth herein Implied warranties including those of merchantability and fitness for a particular purpose are limited to one 1 year from the date of purchase for produc...

Страница 12: ...improper alterations or intervention in the equipment adverse effects from the environment which may impact the equipment itself or the direct vicinity of the equipment or persons in the area To obta...

Отзывы: